Spring 2017 Trigger Summary

From GlueXWiki
Revision as of 07:32, 21 March 2017 by Jrsteven (Talk | contribs) (GTP Trigger Summary Table)

Jump to: navigation, search

GTP Trigger Summary Table

Mask Condition FCAL rings masked Prescale Run Start Run End Date Range Log entry
FCAL-BCAL
0000001 10*FCAL + 2*BCAL > 18000 && FCAL > 200 2 1
BCAL
0000100 BCAL > 18000 N/A 1
PS
0001000 PSC Coincidence N/A 1
FCAL-ST Minimum Bias
0100000 FCAL > 900 && # ST hit > 0 2 2
ST-TAGH Minimum Bias
1000000 ST hit and TAGH hit in energy specified energy range N/A  ?  ?  ?  ?  ?

Front Panel Trigger Summary Table

FP Input FP Bit Run Start Date Start Log entry
FCAL LED 3 11333 4/12/16 3397348
BCAL LED Upstream 9 10506 2/24/16
BCAL LED Downstream 10 10506 2/24/16
Random pulser 12 11299 4/11/16 3397771

Monitoring Configuration File Changes

The configuration files (e.g. FCAL_BCAL_PS_m9.conf) are stored in RCDB for each run, and contain all the relevant configuration variables. This link: Configuration File Changes: Spring 2017 provides a list of when the standard production configuration file changed (according to RCDB), and the difference with the previous configuration file. The specific run numbers for various trigger changes in the table above are derived from these configuration files.