Difference between revisions of "TOF Backgrounds"
From GlueXWiki
(→Items for Discussion) |
|||
Line 11: | Line 11: | ||
== Items for Discussion == | == Items for Discussion == | ||
− | * There seem to be no hits for bars 41-44. Software bug? | + | * There seem to be no hits for bars 41-44. Software bug? |
− | + | ''Yes, it was a mismatch between the names used in the hdds geometry document and those expected in the simulation hits package. This bug was fixed by RTJ on 16-Jan.'' | |
== Plots == | == Plots == |
Revision as of 15:20, 23 January 2007
Back to Background Rate Studies
Detector Configuration
- Double-Hit Resolution: 25 ns
- Threshold: 0.8 MeV
- Maximum Number of Hits: 100
Items for Discussion
- There seem to be no hits for bars 41-44. Software bug?
Yes, it was a mismatch between the names used in the hdds geometry document and those expected in the simulation hits package. This bug was fixed by RTJ on 16-Jan.