Difference between revisions of "TOF Backgrounds"

From GlueXWiki
Jump to: navigation, search
 
Line 15: Line 15:
  
 
== Plots ==
 
== Plots ==
 +
 +
[[Image:tof_rate_v_bar.jpg|frame|center|The characteristic background rate per PMT per bar in the TOF.]]
 +
 +
[[Image:tof_energy.jpg|frame|center|The energy deposition in the TOF for background hits.  There are no surprises here -- log( 2.54 cm * 0.002 GeV / cm ) = -2.3 ]]

Revision as of 23:51, 15 January 2007

Back to Background Rate Studies


Detector Configuration

  • Double-Hit Resolution: 25 ns
  • Threshold: 0.8 MeV
  • Maximum Number of Hits: 100


Items for Discussion

  • There seem to be no hits for bars 41-44. Software bug?


Plots

The characteristic background rate per PMT per bar in the TOF.
The energy deposition in the TOF for background hits. There are no surprises here -- log( 2.54 cm * 0.002 GeV / cm ) = -2.3