Below is tagger trigger timing information I got from Eugene Pasyuk. Note that cables are trimmed so the sum of all delays is the same for all T-counters

delta T
Location
25 ns
tagger radiator to farthest T-counter
20 ns
in T-counter PMT
50 ns
cable to CFD
15 ns
internal CFD
5 ns
to L-R coincidence logic module
5 ns
internal L-R coincidence logic module
10 ns
to Master Or module
20 ns
internal MOR
80 ns
MOR to forward carriage