Difference between revisions of "Tracking-8-26-2021"

From GlueXWiki
Jump to: navigation, search
 
Line 16: Line 16:
 
== Minutes ==
 
== Minutes ==
 
# Run preparations
 
# Run preparations
#* CDC i - ready to go, will start mixing alcohol next Tuesday.
+
#* CDC - ready to go, will start mixing alcohol next Tuesday.
 
#* FDC  
 
#* FDC  
#** Lubomir filled a spread
+
#** Lubomir checked FDC using cosmics and filled the spreadsheet where we compare the problematic channels year-by-year. In short - there are no new problematic channels, most of them were present in the last year check, several were not but were intermittent in the past years.
 +
#** There was some noise in FDC2 Cell1 in run 80135 (8/24 evening) identified as sparking close to the last wire, that stopped now. Will keep an eye on it. 
 
#* fADC125
 
#* fADC125
 
#* GEM-TRD
 
#* GEM-TRD
 
# Tracking
 
# Tracking
 +
#* Alex showed pion and proton pull distribution for different soft version and FDC tilts. After long discussions there have been some new ideas: try to lock FDC and CDC together when do the tilt; use low energy data where we expect more tracks crossing both detectors, also rotate the magnetic field together with the FDC.

Latest revision as of 16:29, 26 August 2021

  1. Instructions for Bluejeans meeting connection
  2. Meeting ID: 290664653
  3. To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.

Thu 8/26/2021 2pm

Agenda

  1. Run preparations
  2. Tracking
  3. Other

Minutes

  1. Run preparations
    • CDC - ready to go, will start mixing alcohol next Tuesday.
    • FDC
      • Lubomir checked FDC using cosmics and filled the spreadsheet where we compare the problematic channels year-by-year. In short - there are no new problematic channels, most of them were present in the last year check, several were not but were intermittent in the past years.
      • There was some noise in FDC2 Cell1 in run 80135 (8/24 evening) identified as sparking close to the last wire, that stopped now. Will keep an eye on it.
    • fADC125
    • GEM-TRD
  2. Tracking
    • Alex showed pion and proton pull distribution for different soft version and FDC tilts. After long discussions there have been some new ideas: try to lock FDC and CDC together when do the tilt; use low energy data where we expect more tracks crossing both detectors, also rotate the magnetic field together with the FDC.