#* CDC - the CDC bubbler stopped, Beni will look at it, most likely needs oil.
 
#* CDC - the CDC bubbler stopped, Beni will look at it, most likely needs oil.
#* FDC  
+
#* FDC In addition to what was posted at the last tracking meeting as an action plan: the FDC spare package was moved to EEL126. Tim proposed as another option to use a pump at the supply line combined with reversing the gas flow. Beni - might be dangerous as the foils bend in the other direction. As a last resort, if reversing doesn't unclog the line, we can use the gauge line (that is used to measure the pressure inside the cell) as an exhaust - requires a very delicate pressure balance, but should work.
In addition to what was posted at the last tracking meeting as an action plan: the FDC spare package was moved to EEL126. Tim proposed as another option to use a pump at the supply line combined with reversing the gas flow. Beni - might be dangerous as the foils bend in the other direction. As a last resort, if reversing doesn't unclog the line, we can use the gauge line (that is used to measure the pressure inside the cell) as an exhaust - requires a very delicate pressure balance, but should work.
+
 
# Tracking
 
# Tracking

Revision as of 16:39, 9 September 2021

  1. Instructions for Bluejeans meeting connection
  2. Meeting ID: 290664653
  3. To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.

Thu 9/9/2021 2pm

Agenda

  1. Run preparations
  2. Tracking
    • Simluation of FDC tilt (θx=-0.0275, θy=0.0265), reconstruction with nominal geometry (Alex)
      • π- ,comparison to real data in red
      • proton ,comparison to real data in red
    • Ongoing: study effect on and SDMEs
  3. Other

Minutes

  1. Run preparations
    • CDC - the CDC bubbler stopped, Beni will look at it, most likely needs oil.
    • FDC In addition to what was posted at the last tracking meeting as an action plan: the FDC spare package was moved to EEL126. Tim proposed as another option to use a pump at the supply line combined with reversing the gas flow. Beni - might be dangerous as the foils bend in the other direction. As a last resort, if reversing doesn't unclog the line, we can use the gauge line (that is used to measure the pressure inside the cell) as an exhaust - requires a very delicate pressure balance, but should work.
  2. Tracking