Request:     /FCAL/fcal_parms:0:default:2013-01-17_19-02-26

Constants information:

Table [/FCAL/fcal_parms]
Variation default
Created 2013-01-17 19:02:26
Run range 0 - inf.
Author anonymous
Exact id /FCAL/fcal_parms:0:default:2013-01-17_19-02-26
[Download text data]

Comment:



FCAL data base of constants used in MC

Photon-statistics factor for smearing hit energy (from Crisss MC)
(copied from DFCALMCResponse_factory.cc 7/2/2009 DL)
Single block energy threshold (applied after smearing)
20 MeV, units are in GeV
Attenuation length in cm.
effective speed of light in glass in cm/ns
block width in cm
block length in cm
time windown for two hit separation in ns
maximum number of hits in a single block
threshold applied in a block (in hdgeant)
Note: different unit than for smeared-blocks threshold (see above)
radius of the calorimeter
number of blocks in central row
number of blocks in central column

Data:

FCAL_PHOT_STAT_COEF FCAL_BLOCK_THRESHOLD FCAL_ATTEN_LENGTH FCAL_C_EFFECTIVE FCAL_WIDTH_OF_BLOCK FCAL_LENGTH_OF_BLOCK FCAL_TWO_HIT_RESOL FCAL_MAX_HITS FCAL_THRESH_MEV FCAL_ACTIVE_RADIUS FCAL_CENTRAL_ROW FCAL_CENTRAL_COLUMN
0.035 0.02 100. 15. 4. 45. 75. 100 5. 120. 29 29