BCAL Radiation Length Calculations

Document #:
GlueX-doc-439-v4
Document type:
Technical Note
Submitted by:
Zisis Papandreou
Updated by:
Zisis Papandreou
Document Created:
28 Feb 2005, 09:15
Contents Revised:
18 Jun 2007, 10:11
Metadata Revised:
18 Jun 2007, 10:11
Viewable by:
  • Public document
Modifiable by:
  • Same as Viewable by

Quick Links:
Latest Version

Other Versions:
GlueX-doc-439-v5
18 Jun 2007, 17:00
GlueX-doc-439-v3
17 Apr 2005, 21:56
GlueX-doc-439-v2
28 Feb 2005, 09:28
GlueX-doc-439-v1
28 Feb 2005, 09:21
Abstract:
Analytical calculations of the radiation length for the Barrel Calorimeter of the GlueX Project are presented. These show that the full thickness radiation length ranges from 18-20 X_0 depending on the thickness of the aluminum backing plate and the analytical formalism used.
Files in Document:
Notes and Changes:
ZP checked all numbers in the previous documents and corrected errors in the calculation of Xo using all formulae. The numbers for eqs. 5 and 6 (as calculated by hand and via Mac Grapher equation macros) are in excellent agreement with the PDG values for the elements an mixtures in question and additional ones determined as cross checks.