Line 58: Line 58:
  
 
There are two beam profilers installed in the beam line to measure beam profiles in front of the active collimator and right before the photon beam dump.
 
There are two beam profilers installed in the beam line to measure beam profiles in front of the active collimator and right before the photon beam dump.
 +
Each profiler has two planes scintillator fibers to give X-Y 2D information.
 +
Each plane consists of 64 fibers of 2 mm width and they are readout by four Multi-anode PMTs.
  
Each profiler has two planes scintillator fibers to give X-Y 2D information. Each plane consists of 64 fibers of 2 mm width and they are readout by four Multi-anode PMTs.
+
=== Check Beam Profiler Scaler Rates ===

Revision as of 13:27, 23 October 2014

Active Collimator

Control and DAQ

The Active Collimator screens are here:

Monticello -> BPM (1st blue button) -> Hall D Active Collimator Diagnostics

The preamp gains, 1Hz data and averaging/digital gain are on that screen. Go to the Raw Wire Data button for the individual plots and Time Domain Graph HDACI/O for positions.

High Speed ROOT File Writer

An EPICS IOC server is set up on gluon29.jlab.org:26064 to write the raw waveform data to /gluonraid1/Users/ac directory on demand.

The control of this High Speed DAQ can be found in Hall-D's EPICS GUI:

  1. Open Hall-D CSS EPICS Control if not already available following instructions
  2. From Main Action Bar, open Active Collimator GUI.
  3. Start or Stop the High Speed ROOT File by clicking the button underneath the title.
  4. Once started, make sure the a new ROOT file is created and the File Size is increasing.

In very rare occasions, e.g. some one rebooted the AC DAQ server, the writer IOC needs to be restarted

Reboot using command lines
  1. Log onto gluon29 using hdsys account
  2. telnet localhost 26064
  3. Restart the IOC by keyboard combination Ctrl+X
  4. Exit the IOC proServer by keyboard combination Ctrl+]
  5. Exit the telnet by typing quit

Raw Data Analyzer

From Active Collimator GUI
  1. Click the Analyzer button in the PXI Fast DAQ section.
From a Linux terminal
  1. log onto a gluon machine, e.g. gluon30.jlab.org, using account hdops: ssh -X hdops@gluon30
  2. enter acanalyzer directory: cd ~\acanalyzer
  3. start the analyzer script: ./run
  4. in the analyzer, open a collection of raw data files or a processed ROOT file and start the analysis.

List of EPICS PVs

Collimator

Move Collimator

  1. Open Hall-D CSS EPICS Control if not already available following instructions.
  2. From Main Action Bar, click Motors in BEAM section.
  3. Click Collimator to bring up the Collimator Control GUI.
  4. Click the button corresponding to the desired location to move the collimator. Wait until the Motor is Done.
  5. If the communication to the motor is broken, e.g. pink fields showing, refer to instructions to reboot the IOC.
  6. Make a log entry to HDLOG.

Halo Counters

Beam Profilers

There are two beam profilers installed in the beam line to measure beam profiles in front of the active collimator and right before the photon beam dump. Each profiler has two planes scintillator fibers to give X-Y 2D information. Each plane consists of 64 fibers of 2 mm width and they are readout by four Multi-anode PMTs.

Check Beam Profiler Scaler Rates