− | # Each time the diamond radiator is inserted or its orientation changed, use the nudge buttons to obtain the desired coherent edge fit value, save the new configurations as instructed in | + | # Each time the diamond radiator is inserted or its orientation changed, use the nudge buttons to obtain the desired coherent edge fit value, save the new configurations as instructed in "[[Beam_Line_Detectors_Shift#Adjusting_the_peak_positions | Adjusting the Peak Positions]]" and make a screenshot logentry of the cobrems gui. |
=== Alarms === | === Alarms === |
Revision as of 13:58, 9 March 2020
Contents
Run info logging
- Keep a list of the runs at the end of the shift summary log entry, eg https://logbooks.jlab.org/entry/3795057
- Keep the runs to 2h real-time at most. Calibrations drifts are noticeable after about 2h.
- Write run info into the DAQ run comments box at the start of the run and save it.
- Make sure that the paper list of runs is kept up to date.
Monitoring
- Half-way through each run, post the rootspy monitoring histograms to the logbook and reset them. Post the new plots at the end of the run.
- Make a screenshot of the GlueX overview CSS logentry mid-shift.
- Remind the shift worker to complete the shift checklist.
- Watch the beam monitoring stripcharts, currently using beam_instability_monitoring configuration, & post to the logbook at the end of the shift
- New, maybe temporary: if PS coincidence rates drop by 30% or more, do harp scans (MCC & ours)
Changing radiators
- Each time the amorphous radiator is inserted, make a new AMO reference with beam on.
- Each time the diamond radiator is inserted or its orientation changed, use the nudge buttons to obtain the desired coherent edge fit value, save the new configurations as instructed in " Adjusting the Peak Positions" and make a screenshot logentry of the cobrems gui.
Alarms
- When acknowledging alarms for mechanical and DIRC, acknowledge them at the lowest level of the tree. This is to avoid sending 'OK' messages to the on-call phones for all the branches of the tree which were not alarming.
- Make separate logbook entries for worrying alarms & contact experts as needed.
Beam-Time Accounting (BTA) Guidelines
Access
- We keep a list of requests for opportunistic access on the whiteboard. We also have to keep a list of who is actually in the hall during accesses.