Content:
# DSC2_WIDTH 20 40 <- TDC width (ns), TRG width (ns)
# DSC2_THRESHOLD 20 50 <- board threshold: TDC threshold (mV), TRG threshold (mV)
#
# TS_TRIG_TYPE 1 - Internal Pulser
# 2 - External FP
# 4 - GTP
# 6 - GTP + External
#
#
# TS_FP_INPUTS - List of enabled FP inputs
#
#
# TS_SOFT_TRIG
# Trigger type (type 1 or 2 for playback)
# Number of events to trigger
# Period multiplier (depends on range 0-0x7FFF)
# Range 1 - min 120ns, increments of 30ns up to 983.13u
# 2 - min 120ns, increments of 30.72us up to 1.007s
#
#
# TI_MASTER 1 - Stand alone with master TI
#
# TI_MASTER_TRIG 1 - soft, 2 - external pulser, 3 - playback
#
# TI_SOFT_TRIG
# Trigger type (type 1 or 2 for playback)
# Number of events to trigger
# Period multiplier (depends on range 0-0x7FFF)
# Range 1 - min 120ns, increments of 30ns up to 983.13u
# 2 - min 120ns, increments of 30.72us up to 1.007s
#
# F1TDC_CLOCK 0 <- Clock Source (0 = Internal 32 MHz)
# (1 = External 31.25 MHz)
# F1TDC_VERSION 2 <- Module Version (2 = High Resolution, synchronous, 32 channels)
# (3 = Normal Resolution, synchronous, 48 channels)
# F1TDC_BIN_SIZE 0.056 <- Bin size (ns)
# F1TDC_LATENCY 3000.0 <- Trigger latency (ns)
# F1TDC_WINDOW 1000.0 <- Trigger window (ns)
==========================
TRIGGER
==========================
USE_PLAYBACK 0
TI_MASTER 1
TI_MASTER_TRIG 2
TI_FP_INPUTS 1
# TI_FP_INPUTS 3
TI_SOFT_TRIG 1 65000 0x7FF 1
# TI_FIBER_EN 5
TI_FIBER_LATENCY_OFFSET 0xCA
BLOCKLEVEL 1
BUFFERLEVEL 1
==========================
GLOBAL
==========================
F1TDC_BIN_SIZE 0.058
==========================
ST
==========================
FADC250_MODE 10
#FADC250_W_OFFSET 450
FADC250_W_OFFSET 240
FADC250_W_WIDTH 100
FADC250_NSB 5
FADC250_NSA 20
FADC250_NPEAK 1
FADC250_READ_THR 200
FADC250_TRIG_BL 100
FADC250_TRIG_THR 4050
FADC250_TRIG_NSB 3
FADC250_TRIG_NSA 15
FADC250_COM_DIR /gluex/CALIB/ALL/fadc250/default
FADC250_COM_VER default
FADC250_USER_DIR /home/
FADC250_USER_VER
CTP_USE 0
# F1 TDC
F1TDC_WINDOW 600
F1TDC_LATENCY 2100
F1TDC_CLOCK 1
# LE discriminator
DSC2_WIDTH 40 40
DSC2_THRESHOLD 50 60
==========================
CCAL
==========================
FADC250_MODE 10
FADC250_W_OFFSET 190
FADC250_W_WIDTH 100
FADC250_NSB 5
FADC250_NSA 20
FADC250_NPEAK 3
FADC250_NSAT 2
FADC250_READ_THR 20
FADC250_TRIG_BL 100
# Used for cosmic
# FADC250_TRIG_THR 140
FADC250_TRIG_THR 105
FADC250_TRIG_NSB 3
FADC250_TRIG_NSA 15
FADC250_COM_DIR /gluex/CALIB/ALL/fadc250/default
FADC250_COM_VER default
FADC250_USER_DIR /home/
FADC250_USER_VER
CTP_USE 0