Mcsmear 20161214

From GlueXWiki
Jump to: navigation, search


Delta T Resolutions

Mean resolutions (integrated over momentum)

Detector Recon ver03 Sim 1.2 test
BCAL chg 216 ps 180 ps
BCAL neut 190 ps 224 ps
FCAL chg 0.59 ns 0.62 ns
FCAL neut 0.50 ns 0.51 ns
SC 246 ps 315 ps
TOF 104 ps 70 ps

Data is from RP-2016-02 run 11512

Plots

SC Delta T

20161214 data SC res.png 20161214 mc SC res.png
DATA MC

TOF Delta T

20161214 data TOF res.png 20161214 mc TOF res.png
DATA MC

BCAL Delta T [neutrals]

20161214 data BCAL neut res.png
DATA
20161214 mc BCAL neut res.png
MC

BCAL Delta T [charged]

20161214 data BCAL chg res.png 20161214 mc BCAL chg res.png
DATA MC

FCAL Delta T [neutrals]

20161214 data FCAL neut res.png
DATA
20161214 mc FCAL neut res.png
MC

FCAL Delta T [charged]

20161214 data FCAL chg res.png 20161214 mc FCAL chg res.png
DATA MC