Configurations for Fcal calorimter insert, assume sigma_E/E = c1/sqrt(E) + c2/E + c3, and sigma_x = q1/sqrt(E) + q2/E + q3
Configuration Block Size (mm2) Length(MM) X0 (mm) Sum X0 Moliere Radius (mm) Delta SC (mm) Delta Pb (mm) c1 c2 c3 q1 q2 q3
Pb glass F8-00 40x40 450 31 14.5 43 - - 5.0 0 2.0 6.4 0 0
Pb glass F108 40x40 450 31? 14.5 - - 6.0 0 2.4 6.4 0 0
Shashlyk COMPASS 38x38 450 (388) 15.6 25 1.5 0.75 4.8-6.6 0 0.1-1 5.0 0 0.1
Shashlyk PANDA 110x110 675 34 20 59 1.5 0.275 2.8 0 1.3 15.4 0 3.1
Shashlyk KOPIO PMT 110x110 525 37 14.3 1.5 0.25 3.59 0.9 1.1 15.4? 0 3.1?
Shashlyk KOPIO APD 110x110 525 37 14.3 1.5 0.25 2.77 0.27 1.7 15.4? 0 3.1?
PbWO4 PRIMEX 20.5x20.5 180 8.9 20 21.9 - - 2.6 - - 3.2? 0 0