Spring 2018 Trigger Summary

From GlueXWiki
Jump to: navigation, search

GTP Trigger Summary Table

Mask Condition FCAL rings masked Prescale Run Start Run End Date Range Log entry
FCAL-BCAL
000000001 25*FCAL + 1*BCAL > 45000 && FCAL > 200 2 None 40856 EOR Full Run Period
BCAL
000000100 BCAL > 54000 N/A None 40856 EOR Full Run Period
PS
000001000 PSC Coincidence N/A None 40856 EOR Full Run Period
FCAL-BCAL-ST
010000000 25*FCAL + 1*BCAL > 45000 && FCAL > 200 && # ST hit > 0 2 None 41090 41102
ST-TAGH Minimum Bias
100000000 ST hit and TAGH hit with roughly 9.8 < Eγ < 10.2 N/A None 41263 41263

Front Panel Trigger Summary Table

The 4 Front Panel triggers listed here were included in the production configuration for the full Spring 2018 Run Period.

FP Input FP Bit
FCAL LED 3
BCAL LED Upstream 9
BCAL LED Downstream 10
Random pulser 12

Monitoring Configuration File Changes

The configuration files (e.g. FCAL_BCAL_PS_m9.conf) are stored in RCDB for each run, and contain all the relevant configuration variables. This link: Configuration File Changes: Spring 2018 provides a list of when the standard production configuration file changed (according to RCDB), and the difference with the previous configuration file. The specific run numbers for various trigger changes in the table above are derived from these configuration files.

Summary of Configuration Changes

Parameter Changed Run Start Comment
DSC2_COM 40941 TAGM discriminator threshold modified
FADC250_W_WIDTH and FADC250_READ_THR 41041 TPOL readout window widened and threshold raised
FADC250_USER_VER 41066 Modification to FCAL ring masking in L1 trigger
TRIG_TYPE 41090 Add FCAL-BCAL-ST trigger to the standard trigger mix
FADC250_W_WIDTH and FADC250_READ_THR 41099 TPOL readout window lowered and threshold lowered (revert change in 41041)
TRIG_TYPE 41102 Remove FCAL-BCAL-ST trigger to the standard trigger mix
FADC125_COM_VER 41202 Update CDC thresholds (Naomi)
FADC125_W_OFFSET 41482 Move hits 160 ns closer to the beginning of the time window to reduce "shadowing" of signal hits
FADC125_W_WIDTH 41507 Shorten CDC readout window 200 -> 174 samples (208 ns shorter).
FADC125_MODE 41508 Switch to reading out CDC pulse integral and peak (mode 3) for the CDC. Before this only the high resolution peak was in the readout (mode 5).