Revision as of 08:03, 24 April 2024
10:00 EDT (JLab time) Weekly Meeting
zoom meeting: zoom link
Contents
Action Items
Agenda
- Previous CPP meeting: No agenda. Problems accessing JLab web pages from home.
- Announcements
- Action Items
- Calibrations
- TOF: Full calibration complete. Tested one run, looks very good, resolution below 100ps (for mean-time). CCDB has been updated.
- FCAL: Calibration complete.
- BCAL: Finished. Running checks now.
- CDC: calibration is done. Naomi refined the gains again, based on monitoring version 14. No plots yet.
- FDC: Keigo, done.
- CTOF, FMWPC:
- Digihit integral vs peak 2-d plots for groups of 24 MWPC channels show noise dependence on hit multiplicity in the group.
plots made for the entire group, file name legend: 1st number - MWPC#, 2nd - 24 wires group #, 3rd - one for 1...2 hits in the group, five for 10 or more hits
- Digihit integral vs peak 2-d plots for groups of 24 MWPC channels show noise dependence on hit multiplicity in the group.
- Tagger-Mic, PS, TPOL: ?
- ver10: mic. and hod. timining mostly ok., needs some tweaking of individual channels. PS timing itself looks ok however the relative timing between PS and tagger is off by 4ns(always), this inhibits to do and accidental scaling factor calibration. One block of 5 microscope columns are off regarding energy calibration, it seems the ordering is switched (this seems to be also true for the 80k run period and the 110k run period).
- ver11: looks worse regarding timing, e.g. tagger time minus RF time is off by 4ns most of the time., tagger time minus PS time is still off by 4ns
- tagger microscope walk correction does not work well for all run periods after fall 2021. Ellie Prather from UCON is working on this issue.
- Accidental Scaling Factor calibration requires Tagger and PS calibration.
- Energy calibration of tagger microscope is ok, the issue is in some "cable swap" that was not yet addressed on the translation table see: logbook
- CCDB Constants Status (Elton)
- Data Analysis
- update (Iesa)
- CTOF and MWPC Offline Monitoring (Albert)
- Wiki Page Analysis_Overview
- Documentation
- Upcoming Presentations
- Other business
- Next meeting
Minutes
Attending:
Docs/Files
in: /u/group/halld/www/halldweb/html/talks/2024/CPP/ link: This directory is accessible from the web at https://halldweb.jlab.org/talks/2024/CPP