Difference between revisions of "Spring 2018 Trigger Summary"
From GlueXWiki
(Created page with "__TOC__ = GTP Trigger Summary Table = {| class="wikitable" |- ! Mask ! Condition ! FCAL rings masked ! Prescale ! Run Start ! Run End ! Date Range ! Log entry |- | colspan="...") |
|||
(8 intermediate revisions by 2 users not shown) | |||
Line 20: | Line 20: | ||
| 2 | | 2 | ||
| None | | None | ||
− | | | + | | 40856 |
− | | | + | | EOR |
| Full Run Period | | Full Run Period | ||
| | | | ||
Line 31: | Line 31: | ||
| N/A | | N/A | ||
| None | | None | ||
− | | | + | | 40856 |
− | | | + | | EOR |
| Full Run Period | | Full Run Period | ||
| | | | ||
Line 42: | Line 42: | ||
| N/A | | N/A | ||
| None | | None | ||
− | | | + | | 40856 |
− | | | + | | EOR |
| Full Run Period | | Full Run Period | ||
| | | | ||
Line 53: | Line 53: | ||
| 2 | | 2 | ||
| None | | None | ||
− | | | + | | 41090 |
− | | | + | | 41102 |
− | | | + | | |
− | | | + | | |
|- | |- | ||
| colspan="8" style="text-align: center;" | '''ST-TAGH Minimum Bias''' | | colspan="8" style="text-align: center;" | '''ST-TAGH Minimum Bias''' | ||
Line 64: | Line 64: | ||
| N/A | | N/A | ||
| None | | None | ||
− | | | + | | 41263 |
− | | | + | | 41263 |
− | | | + | | |
− | | | + | | |
|} | |} | ||
= Front Panel Trigger Summary Table = | = Front Panel Trigger Summary Table = | ||
− | The 4 Front Panel triggers listed here were included in the production configuration for the full Spring | + | The 4 Front Panel triggers listed here were included in the production configuration for the full Spring 2018 Run Period. |
{| class="wikitable" | {| class="wikitable" | ||
Line 104: | Line 104: | ||
! Comment | ! Comment | ||
|- | |- | ||
− | | | + | | DSC2_COM |
+ | | 40941 | ||
+ | | TAGM discriminator threshold modified | ||
+ | |- | ||
+ | | FADC250_W_WIDTH and FADC250_READ_THR | ||
+ | | 41041 | ||
+ | | TPOL readout window widened and threshold raised | ||
+ | |- | ||
+ | | FADC250_USER_VER | ||
+ | | 41066 | ||
+ | | Modification to FCAL ring masking in L1 trigger | ||
+ | |- | ||
+ | | TRIG_TYPE | ||
+ | | 41090 | ||
+ | | Add FCAL-BCAL-ST trigger to the standard trigger mix | ||
+ | |- | ||
+ | | FADC250_W_WIDTH and FADC250_READ_THR | ||
+ | | 41099 | ||
+ | | TPOL readout window lowered and threshold lowered (revert change in 41041) | ||
+ | |- | ||
+ | | TRIG_TYPE | ||
+ | | 41102 | ||
+ | | Remove FCAL-BCAL-ST trigger to the standard trigger mix | ||
+ | |- | ||
+ | | FADC125_COM_VER | ||
+ | | 41202 | ||
+ | | Update CDC thresholds (Naomi) | ||
+ | |- | ||
+ | | FADC125_W_OFFSET | ||
| 41482 | | 41482 | ||
− | | Move hits closer to the beginning of the time window to reduce "shadowing" of signal hits | + | | Move hits 160 ns closer to the beginning of the time window to reduce "shadowing" of signal hits |
+ | |- | ||
+ | | FADC125_W_WIDTH | ||
+ | | 41507 | ||
+ | | Shorten CDC readout window 200 -> 174 samples (208 ns shorter). | ||
+ | |- | ||
+ | | FADC125_MODE | ||
+ | | 41508 | ||
+ | | Switch to reading out CDC pulse integral and peak (mode 3) for the CDC. Before this only the high resolution peak was in the readout (mode 5). | ||
|} | |} |
Latest revision as of 07:16, 6 March 2018
Contents
GTP Trigger Summary Table
Mask | Condition | FCAL rings masked | Prescale | Run Start | Run End | Date Range | Log entry |
---|---|---|---|---|---|---|---|
FCAL-BCAL | |||||||
000000001 | 25*FCAL + 1*BCAL > 45000 && FCAL > 200 | 2 | None | 40856 | EOR | Full Run Period | |
BCAL | |||||||
000000100 | BCAL > 54000 | N/A | None | 40856 | EOR | Full Run Period | |
PS | |||||||
000001000 | PSC Coincidence | N/A | None | 40856 | EOR | Full Run Period | |
FCAL-BCAL-ST | |||||||
010000000 | 25*FCAL + 1*BCAL > 45000 && FCAL > 200 && # ST hit > 0 | 2 | None | 41090 | 41102 | ||
ST-TAGH Minimum Bias | |||||||
100000000 | ST hit and TAGH hit with roughly 9.8 < Eγ < 10.2 | N/A | None | 41263 | 41263 |
Front Panel Trigger Summary Table
The 4 Front Panel triggers listed here were included in the production configuration for the full Spring 2018 Run Period.
FP Input | FP Bit |
---|---|
FCAL LED | 3 |
BCAL LED Upstream | 9 |
BCAL LED Downstream | 10 |
Random pulser | 12 |
Monitoring Configuration File Changes
The configuration files (e.g. FCAL_BCAL_PS_m9.conf) are stored in RCDB for each run, and contain all the relevant configuration variables. This link: Configuration File Changes: Spring 2018 provides a list of when the standard production configuration file changed (according to RCDB), and the difference with the previous configuration file. The specific run numbers for various trigger changes in the table above are derived from these configuration files.
Summary of Configuration Changes
Parameter Changed | Run Start | Comment |
---|---|---|
DSC2_COM | 40941 | TAGM discriminator threshold modified |
FADC250_W_WIDTH and FADC250_READ_THR | 41041 | TPOL readout window widened and threshold raised |
FADC250_USER_VER | 41066 | Modification to FCAL ring masking in L1 trigger |
TRIG_TYPE | 41090 | Add FCAL-BCAL-ST trigger to the standard trigger mix |
FADC250_W_WIDTH and FADC250_READ_THR | 41099 | TPOL readout window lowered and threshold lowered (revert change in 41041) |
TRIG_TYPE | 41102 | Remove FCAL-BCAL-ST trigger to the standard trigger mix |
FADC125_COM_VER | 41202 | Update CDC thresholds (Naomi) |
FADC125_W_OFFSET | 41482 | Move hits 160 ns closer to the beginning of the time window to reduce "shadowing" of signal hits |
FADC125_W_WIDTH | 41507 | Shorten CDC readout window 200 -> 174 samples (208 ns shorter). |
FADC125_MODE | 41508 | Switch to reading out CDC pulse integral and peak (mode 3) for the CDC. Before this only the high resolution peak was in the readout (mode 5). |