EM background: <math>40~kHz/straw</math>or <math>267~Hz/cm</math> | EM background: <math>40~kHz/straw</math>or <math>267~Hz/cm</math> | ||
− | * 1 year of running (= 1/3 year beam on target) = <math>1.1\cdot 10^{7}s \times 267 e | + | * 1 year of running (= 1/3 year beam on target) = <math>1.1\cdot 10^{7}s \times 267 \frac{e}{s\cdot cm} \times 1.60\cdot10^{-19}C/e \times 2\cdot 10^{5} = 9.0 \cdot 10^{-5} C/cm</math> |
* Irradiation dose = 44 years of running | * Irradiation dose = 44 years of running |
Revision as of 16:23, 5 November 2009
Dose (C/cm):
- Lamina 300 A:
- Lamina 12 m:
- CMU mylar:
- CMU kapton:
EM background: or
- 1 year of running (= 1/3 year beam on target) =
- Irradiation dose = 44 years of running