Difference between revisions of "Dec 17, 2009 Readout"
From GlueXWiki
(→Tentative Agenda: Internal Review of SiPM Option) |
|||
Line 43: | Line 43: | ||
= Minutes = | = Minutes = | ||
+ | Attending: Matt, Ryan (IU); George, Zisis (UofR); Beni, Elton, Eugne, Carl, John, Chuck, Tim, Mark, Howard, Stepan, Fernando | ||
+ | |||
+ | # Announcements | ||
+ | # Review of Action Items | ||
+ | #* Carl updated the amplitude vs incident photon plot in his slides. He has not yet extended the measurement to higher light yields where saturation is expected. | ||
+ | # Overview (Elton) | ||
+ | ## [[Media:Bcal guides sipm3.pdf | Segmentation for all SiPM option]] Number of SiPMs = (24+16)*2*48 = 3840 | ||
+ | # SiPM - update | ||
+ | ## Electrical Tests (Fernando) | ||
+ | ## PDE/Dark Rate (Carl) | ||
+ | ## Acceleration Tests (Carl) | ||
+ | ## Tests still planned | ||
+ | # Detailing the SiPM option | ||
+ | ## Light collection and dynamic range (number of photons expected per sensor) | ||
+ | ## Cooling / temperature stabilization (specifications) | ||
+ | ## Output (gain and PDE) stabilization and summing | ||
+ | ## Geometry model | ||
+ | # Discussion - path forward | ||
+ | ## [[Media:Bcal readout baseline Dec09.pdf | Baseline Schedule]] | ||
+ | # Discussion - MOU with USM |
Revision as of 15:06, 17 December 2009
Teleconference Time: 11:00 a.m. EST
- ESNET and EVO session
- Phone:
- +1-800-377-8846 : US
- +1-888-276-7715 : Canada
- +1-302-709-8424 : International
- then enter participant code: 77438230# (remember the "#"). Phone connection only upon request.
Contents
Items for followup from previous meeting
- Order prototype light guides (Elton)
- Determine the amplitude vs Npe for the light sensors (Carl)
- Testing of new modules to determine the range of phoelectrons expected.
Documents to Review
- Plan for SiPM Testing (Carl and Fernando)
Tentative Agenda: Internal Review of SiPM Option
- Announcements
- Review of Action Items
- Overview (Elton)
- Segmentation for all SiPM option Number of SiPMs = (24+16)*2*48 = 3840
- SiPM - update
- Electrical Tests (Fernando)
- PDE/Dark Rate (Carl)
- Acceleration Tests (Carl)
- Tests still planned
- Detailing the SiPM option
- Light collection and dynamic range (number of photons expected per sensor)
- Cooling / temperature stabilization (specifications)
- Output (gain and PDE) stabilization and summing
- Geometry model
- Discussion - path forward
- Discussion - MOU with USM
Minutes
Attending: Matt, Ryan (IU); George, Zisis (UofR); Beni, Elton, Eugne, Carl, John, Chuck, Tim, Mark, Howard, Stepan, Fernando
- Announcements
- Review of Action Items
- Carl updated the amplitude vs incident photon plot in his slides. He has not yet extended the measurement to higher light yields where saturation is expected.
- Overview (Elton)
- Segmentation for all SiPM option Number of SiPMs = (24+16)*2*48 = 3840
- SiPM - update
- Electrical Tests (Fernando)
- PDE/Dark Rate (Carl)
- Acceleration Tests (Carl)
- Tests still planned
- Detailing the SiPM option
- Light collection and dynamic range (number of photons expected per sensor)
- Cooling / temperature stabilization (specifications)
- Output (gain and PDE) stabilization and summing
- Geometry model
- Discussion - path forward
- Discussion - MOU with USM