Line 44: Line 44:
 
'''Collaboration Meeting Agenda'''
 
'''Collaboration Meeting Agenda'''
  
* Elton noted that it is near impossible to have a 15 minute talk at a collaboration meeting.  Elliott will rework the schedule.
+
* Elton noted that it is near impossible for a talk to last 15 minutes or less at a collaboration meeting.  Elliott will rework the schedule.
  
  
Line 50: Line 50:
  
 
* Stresses in one of the windings in coil 2 are too high, may need internal reinforcement.
 
* Stresses in one of the windings in coil 2 are too high, may need internal reinforcement.
* PLC components here.  Mark S about 70% done ordering remaining instrumentation.
+
* PLC components are all here.  Mark W has taken what he needs, the rest is in F117.
 +
* Mark S about 70% done ordering remaining instrumentation.
 
* Mark W will set up in Steve Lassiter's lab in the ARC building.
 
* Mark W will set up in Steve Lassiter's lab in the ARC building.
 
* Elton suggested it is time to put the coil test schedule in FastTrack.
 
* Elton suggested it is time to put the coil test schedule in FastTrack.
Line 62: Line 63:
 
* First version of browser, bug reports and comments are welcome.
 
* First version of browser, bug reports and comments are welcome.
 
* Has special mode to display CODA daLogMsg() messages.
 
* Has special mode to display CODA daLogMsg() messages.
* CodaObject library now instrumented with daLogMsg() calls.
+
* CodaObject library now instrumented with daLogMsg() calls.  This may be a reason for test setups to upgrade to the latest codaObject library.
 
* GUI can plot timeline of individual message values, or display array as histogram.
 
* GUI can plot timeline of individual message values, or display array as histogram.
* Distributed via CODA web and ftp sites.
+
* Package distributed via CODA ftp site (ftp.jlab.org/pub/coda/cMb).
  
  
Line 70: Line 71:
  
 
* Beni found lots of noise coming out of CAEN HV crates in the FDC test setup, taking steps to isolate them.  
 
* Beni found lots of noise coming out of CAEN HV crates in the FDC test setup, taking steps to isolate them.  
* FADC250 identified for FSU, but do they really need it, or is it a diversion?
+
* FADC250 allocated for FSU.  Do they really need it, or is it a diversion?

Revision as of 15:05, 20 August 2009

Agenda


Time/Location

1:30 PM Wed 19-Aug-2009 CC F326


Announcements

Next Meeting

1:30 PM Wed 2-Sep-2009


New Action Items from this Meeting

  • Put coil test schedule in FastTrack - Elliott


Minutes

Attendees: Elliott W, Beni Z, Simon T, Mark I, Dave D, Elton S, Vardan G, Alex S.


Note: Many people were out of town or on vacation, so some topics were postponed until next meeting. Also the JLab Luau started at 3pm so we had to end before then!


Collaboration Meeting Agenda

  • Elton noted that it is near impossible for a talk to last 15 minutes or less at a collaboration meeting. Elliott will rework the schedule.


Solenoid Coil Test

  • Stresses in one of the windings in coil 2 are too high, may need internal reinforcement.
  • PLC components are all here. Mark W has taken what he needs, the rest is in F117.
  • Mark S about 70% done ordering remaining instrumentation.
  • Mark W will set up in Steve Lassiter's lab in the ARC building.
  • Elton suggested it is time to put the coil test schedule in FastTrack.


cMsg Browser

Vardan demonstrated a general purpose graphical cMsg browser.

  • cMsg is foundation of CODA run control. Will be used extensively in Hall D.
  • First version of browser, bug reports and comments are welcome.
  • Has special mode to display CODA daLogMsg() messages.
  • CodaObject library now instrumented with daLogMsg() calls. This may be a reason for test setups to upgrade to the latest codaObject library.
  • GUI can plot timeline of individual message values, or display array as histogram.
  • Package distributed via CODA ftp site (ftp.jlab.org/pub/coda/cMb).


Electronics

  • Beni found lots of noise coming out of CAEN HV crates in the FDC test setup, taking steps to isolate them.
  • FADC250 allocated for FSU. Do they really need it, or is it a diversion?