Difference between revisions of "Mattione Update 06012011"
From GlueXWiki
Line 3: | Line 3: | ||
* 10000 generated events: ~49% reconstruction efficiency. | * 10000 generated events: ~49% reconstruction efficiency. | ||
* However, very significant high-mass tail. | * However, very significant high-mass tail. | ||
− | [[Image:Mattione_Update_06012011_InvMass_X2000.gif|thumb|left|600px]] | + | [[Image:Mattione_Update_06012011_InvMass_X2000.gif|thumb|left|600px|Code as of 06/01/2011]] |
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
Line 9: | Line 9: | ||
* π<sup>0</sup>: The combination of tracks yielding a mass closest to the π<sup>0</sup>. | * π<sup>0</sup>: The combination of tracks yielding a mass closest to the π<sup>0</sup>. | ||
* Significantly worse resolution than originally. | * Significantly worse resolution than originally. | ||
− | [[Image:Mattione_Update_06012011_InvMass_Pi0.gif|thumb|left|600px]] | + | [[Image:Mattione_Update_06012011_InvMass_Pi0.gif|thumb|left|600px|Code as of 06/01/2011]] |
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
* π<sup>0</sup>: Original version on b1pi wiki page: | * π<sup>0</sup>: Original version on b1pi wiki page: | ||
− | [[Image:20100114_mass_pi0.png|thumb|left|600px]] | + | [[Image:20100114_mass_pi0.png|thumb|left|600px|Original version on b1pi wiki page]] |
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
Line 19: | Line 19: | ||
* γ's were reconstructed with p & E = 0 until a fix by David Lawrence this morning. | * γ's were reconstructed with p & E = 0 until a fix by David Lawrence this morning. | ||
* For each of the generated photons that were matched with reconstructed photons, Δp (generated - reconstructed) vs generated p: | * For each of the generated photons that were matched with reconstructed photons, Δp (generated - reconstructed) vs generated p: | ||
− | [[Image:Mattione_Update_06012011_PhotonDeltaPVsP.gif|thumb|left|600px|Δp (generated - reconstructed) vs generated p]] | + | [[Image:Mattione_Update_06012011_PhotonDeltaPVsP.gif|thumb|left|600px|Code as of 06/01/2011, Δp (generated - reconstructed) vs generated p]] |
<br style="clear:both;"/> | <br style="clear:both;"/> |
Revision as of 11:23, 1 June 2011
X(2000)0 Mass
- X(2000)0: The combination of tracks yielding a mass closest to the X(2000)0.
- 10000 generated events: ~49% reconstruction efficiency.
- However, very significant high-mass tail.
π0 Mass
- π0: The combination of tracks yielding a mass closest to the π0.
- Significantly worse resolution than originally.
- π0: Original version on b1pi wiki page:
γ Reconstruction
- γ's were reconstructed with p & E = 0 until a fix by David Lawrence this morning.
- For each of the generated photons that were matched with reconstructed photons, Δp (generated - reconstructed) vs generated p: