Difference between revisions of "CDC finding signal duration"
From GlueXWiki
Line 21: | Line 21: | ||
{| border="0" cellpadding="2" | {| border="0" cellpadding="2" | ||
|[[Image:run_31809_pklength_track101.png|thumb|x300px|run 31809 (horizontal)]] | |[[Image:run_31809_pklength_track101.png|thumb|x300px|run 31809 (horizontal)]] | ||
− | |[[Image: | + | |[[Image:run_31810_pklength_track101.png|thumb|x300px|run 31810 (tilted 45deg)]] |
|} | |} |
Revision as of 16:25, 5 July 2012
Try this: search backwards from end sample, looking for change in ADC value going below -2sigma (or -1sigma if -2sigma not found, or min value if -1sigma not found), then search forwards until change in ADC value goes +ve.
That gives the following for the above events: (run 31810) 260, 258, 295, 293, 264 and (run 31809) 242, 230, 281, 301, 268