Difference between revisions of "Minutes-9-17-2015"
From GlueXWiki
Line 39: | Line 39: | ||
== FDC update == | == FDC update == | ||
− | - Cody and Sergey were able to run the new firmware with 1000-sample window. | + | - Cody and Sergey were able to run the new firmware with 1000-sample window. First plot above shows the signals (from bottom to top) from the first chamber wires, first chamber cathodes, and second chamber cathodes, when using 90Sr source; a second cell wire used for triggering. The max drift time (>8usec) looks bigger than expected from Garfield ~5 usec. This indicates different gas mixture (nominally 90/10 Ar/CO2) or weaker fields. Second plot shows a result with 55Fe source: total charge on x vs width of the signal in time, the later estimated by the (total charge)/(max amplitude). |
== Electronics == | == Electronics == |
Revision as of 16:53, 24 September 2015
September 17, 2015 Drift Chamber meeting
Connection
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Agenda