Difference between revisions of "Minutes-9-17-2015"

From GlueXWiki
Jump to: navigation, search
Line 39: Line 39:
 
== FDC update ==
 
== FDC update ==
  
- Cody and Sergey were able to run the new firmware with 1000-sample window. The two plots above demonstrate  
+
- Cody and Sergey were able to run the new firmware with 1000-sample window. First plot above shows the signals (from bottom to top) from the first chamber wires, first chamber cathodes, and second chamber cathodes, when using 90Sr source; a second cell wire used for triggering. The max drift time (>8usec) looks bigger than expected from Garfield ~5 usec. This indicates different gas mixture (nominally 90/10 Ar/CO2) or weaker fields. Second plot shows a result with 55Fe source: total charge on x vs width of the signal in time, the later estimated by the (total charge)/(max amplitude).  
  
 
== Electronics ==
 
== Electronics ==

Revision as of 16:53, 24 September 2015

September 17, 2015 Drift Chamber meeting

Connection

  1. Instructions for Bluejeans meeting connection
  2. Meeting ID: 290664653
  3. To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.

Agenda

  1. Collaboration meeting agenda
  2. CDC update
  3. FDC update
    • studies with 90Sr and 55Fe on spare package: [2], [3]
  4. Electronics
  5. Engineering
    • MFC issues [4]
  6. Other