Monitoring System Requirements
From GlueXWiki
Monitoring Requirements Table
Characteristic | Fcal | Bcal | TOF | Start |
---|---|---|---|---|
Light uniformity channel-to-channel | ≤ 15% | |||
Dynamic range of input (number of photoelectrons) | typically 100 | 100 up to 800 | ||
Requirement on absolute light input | none (PRIMEX might have) | 150 pe on module | ||
Variation in arrival times of cal pulses | ~3 ns | ≤ 2 ns | ~3ns | ~3ns |
Time stability gain and timing (one channel) | ≤ 10% in 6 months | |||
Temperature stability (likely cause of time stability) | 1o causes 3% gain change | |||
Location of calibration input | From front to monitor rad damage | light guide tapered side | ||
Geometrical constraints | Approximately 90% of front 4x4 cm2 area available | packing of WC and LGs, LED fitting, cable routing |
- Comment: Time (and temperature) stability most important.
- Comment: Option of delivering a range of light intensities important (e.g. using various filter settings).
- Comment from Werner: The flexibility in the use of the LED would be very useful for the start counter. Christina: Still need to test stability.
- Questions to Matt: What uniformity could one expect from the plexiglass input system? How many fibers were used to pulse the plexiglass, i.e. how often were they spaced?
- Comment: Matt drew attention to an LED pulser by Paul Smith which might be a useful reference.