Difference between revisions of "CDC Prototype Studies"

From GlueXWiki
Jump to: navigation, search
(Electronics)
m (Text replacement - "http://argus.phys.uregina.ca/gluex" to "https://halldweb.jlab.org")
 
(11 intermediate revisions by one other user not shown)
Line 2: Line 2:
 
[[dE/dx 350 MeV pions/protons]]
 
[[dE/dx 350 MeV pions/protons]]
  
[[dE/dx 350 MeV pions/kaons/protons]]
+
[[dE/dx 350 MeV pions/koans/protons| dE/dx 350 MeV pions/kaons/protons]]
  
 
[[dE/dx 250 MeV pions/kaons]]
 
[[dE/dx 250 MeV pions/kaons]]
  
 
[[H20 contamination tests]]
 
[[H20 contamination tests]]
 +
 
===Old prototype===
 
===Old prototype===
 
[[CDC_Photos_2008| Photographs of the older, larger, CDC Prototype]]
 
[[CDC_Photos_2008| Photographs of the older, larger, CDC Prototype]]
Line 32: Line 33:
 
[[Heated gas measurements]]
 
[[Heated gas measurements]]
  
== Electronics ==
+
=== Electronics ===
  
[[ASIC meeting June 14, 2010]]
 
  
[[Charge division]]
+
[[Charge division|Old prototype - charge division (to obtain z-position)]]
  
 
[[Measuring Fe-55 X-rays with %2 interposer board]]
 
[[Measuring Fe-55 X-rays with %2 interposer board]]
Line 44: Line 44:
 
[[ASIC design optimizations]]
 
[[ASIC design optimizations]]
  
[http://argus.phys.uregina.ca/gluex/DocDB/0010/001079/006/cdcasic.pdf  ASIC design optimizations tests writeup]
+
[https://halldweb.jlab.org/DocDB/0010/001079/006/cdcasic.pdf  ASIC design optimizations tests writeup]
  
 
[[Shaper gain]]
 
[[Shaper gain]]
Line 54: Line 54:
 
[[CDC High Voltage Board (HVB)]]
 
[[CDC High Voltage Board (HVB)]]
  
[[Pictures| Pictures of electrical connections on large prototype ]]
+
[[Pictures| Photos of electrical connections on large prototype ]]
 +
 
 +
====[[CDC_Preamps| Preamps]]====
  
[[CDC_Preamps| Preamps]]
+
====[[Noise_studies|Noise studies]]====
  
 +
====[[New HVB| New HVB]]====
  
 +
====[[New fADC]]====
  
[[Noise_studies|Noise studies]]
+
====Gas mix problems====
  
=====[[New HVB]]=====
+
[[After_mass_flow_controller_recalibration|Before and after MFC recalibration]]

Latest revision as of 12:38, 14 March 2017

Simulations

dE/dx 350 MeV pions/protons

dE/dx 350 MeV pions/kaons/protons

dE/dx 250 MeV pions/kaons

H20 contamination tests

Old prototype

Photographs of the older, larger, CDC Prototype

New prototype

Energy/Amplitude as a function of drift time

Gas leak tests

Setup and tests

First signals

Gas mixture tests

Pictures of the prototype

Dimensions

Planned mechanical/construction tests

Resolutions

More resolution studies

Heated gas measurements

Electronics

Old prototype - charge division (to obtain z-position)

Measuring Fe-55 X-rays with %2 interposer board

Electronic chain simulation

ASIC design optimizations

ASIC design optimizations tests writeup

Shaper gain

fADC timing

125 MHz Clock test

CDC High Voltage Board (HVB)

Photos of electrical connections on large prototype

Preamps

Noise studies

New HVB

New fADC

Gas mix problems

Before and after MFC recalibration