Difference between revisions of "December 21, 2007 Calorimetry"
From GlueXWiki
(→Agenda) |
(→Minutes) |
||
Line 30: | Line 30: | ||
==Minutes== | ==Minutes== | ||
− | Attendees: | + | Attendees: Alex, Matt, Beni, Mihajlo (Indiana), Elton, Tim (JLab), Elke (DESY), George, Zisis (Regina) |
+ | |||
+ | # '''Previous minutes:''' [[December 14, 2007 Calorimetry]] | ||
+ | #* No comments. | ||
+ | # '''Calorimetry Document Preparation''' | ||
+ | #* ''Resources'': | ||
+ | #* ''Status Quo'': | ||
+ | #* ''Timelines'': | ||
+ | #* ''Reviewers'': | ||
+ | # '''FCAL Hardware/Software''' | ||
+ | #* Mihajlo has been generating gp->b_1pi0 and f_1pi0 (all neutral) final states for reconstruction studies. The learning curve on high multiplicity events is taking more time than anticipated. Hopes to have results to show soon. | ||
+ | #* Alex mentioned that a comparison of Mihajlo's reconstruction with his parametric simulation has been conducted and agrees well. The input of photon detection for the parametric MC was parameterized from Mihajlo's output. For a_0 and a_2 production the realistic acceptance is about 30-35% and agrees between the two analysis. This reconstruction has been updated since the collaboration meeting where a 40% reconstruction efficiency was reported. | ||
+ | #* The reconstructed masses of pi0 is about 10-11 MeV, eta is 35 MeV. The widths agree between full reconstruction and MC. For photons that hit the Fcal only, the pi0 width is about 7 MeV and photons that hit the Bcal only the width is about 11 MeV. | ||
+ | # '''BCAL Hardware/Software''' | ||
+ | #* George reported on the SiPM work. Two new results will be posted to the portal shortly. Conclusions from the Phase I tests are | ||
+ | #** Quality of SiPMs fell below expectations, at least for these early units | ||
+ | #** Factor of 2 variation in gain which is not acceptable | ||
+ | #** The sensor tiles showed extreme sensitivity of electronics to external parameters, such as the power supply and noise. Large pedestal widths are due mainly to the electronics. | ||
+ | #** Tested tiled arrays provide a proof-in-principle of use of detection over a large area, but characteristics are below specifications. | ||
+ | #** Carl asked for the voltage used for the reported tests: The breakdown voltate was 27.3 V, operation was about 28.8 V or about 1.5 V above breakdown. | ||
+ | #** SensL initially did not believe the large gain variations measured, but UofR measurements are reproducible and seem to stand up. | ||
+ | #** SensL has asked UofR to make further tests, specifically to check the connectivity from cell-to-cell, with they will do. |
Revision as of 21:37, 21 December 2007
Connection
- The meeting will be held at 10:00 EST (9:00 CST)
- Phone:
- +1-800-377-8846 : US
- +1-888-276-7715 : Canada
- +1-302-709-8424 : International
- then enter participant code: 39527048# (remember the "#")
Agenda
- Previous minutes: December 14, 2007 Calorimetry
- Calorimetry Document Preparation
- Resources Alex's draft GX_calorimetry).
- Intro: GlueX-doc-856 and Media:reminder2.pdf
- BCAL bullets: Media:BCAL_Highlights.pdf, FCAL list: Media:CalorimetryOutlineDoc.pdf
- DocDB: BCAL Calorimetry Response, BCAL Facts, Amplitude Analysis, SciFi Emission Spectra Analysis
- Resources Alex's draft GX_calorimetry).
- FCAL Hardware/Software
- Light guides: ongoing, update
- Low energy threshold: cosmics/Cherenkov: ongoing, update
- Hadronic backgrounds: ongoing, update
- BCAL Hardware/Software
- SiPM Arrays: defect/distortion tests
- Outer Bcal Light Guides: Preliminary notes (ES)
- Any other business
- Tracker: ActionItemTracker
Minutes
Attendees: Alex, Matt, Beni, Mihajlo (Indiana), Elton, Tim (JLab), Elke (DESY), George, Zisis (Regina)
- Previous minutes: December 14, 2007 Calorimetry
- No comments.
- Calorimetry Document Preparation
- Resources:
- Status Quo:
- Timelines:
- Reviewers:
- FCAL Hardware/Software
- Mihajlo has been generating gp->b_1pi0 and f_1pi0 (all neutral) final states for reconstruction studies. The learning curve on high multiplicity events is taking more time than anticipated. Hopes to have results to show soon.
- Alex mentioned that a comparison of Mihajlo's reconstruction with his parametric simulation has been conducted and agrees well. The input of photon detection for the parametric MC was parameterized from Mihajlo's output. For a_0 and a_2 production the realistic acceptance is about 30-35% and agrees between the two analysis. This reconstruction has been updated since the collaboration meeting where a 40% reconstruction efficiency was reported.
- The reconstructed masses of pi0 is about 10-11 MeV, eta is 35 MeV. The widths agree between full reconstruction and MC. For photons that hit the Fcal only, the pi0 width is about 7 MeV and photons that hit the Bcal only the width is about 11 MeV.
- BCAL Hardware/Software
- George reported on the SiPM work. Two new results will be posted to the portal shortly. Conclusions from the Phase I tests are
- Quality of SiPMs fell below expectations, at least for these early units
- Factor of 2 variation in gain which is not acceptable
- The sensor tiles showed extreme sensitivity of electronics to external parameters, such as the power supply and noise. Large pedestal widths are due mainly to the electronics.
- Tested tiled arrays provide a proof-in-principle of use of detection over a large area, but characteristics are below specifications.
- Carl asked for the voltage used for the reported tests: The breakdown voltate was 27.3 V, operation was about 28.8 V or about 1.5 V above breakdown.
- SensL initially did not believe the large gain variations measured, but UofR measurements are reproducible and seem to stand up.
- SensL has asked UofR to make further tests, specifically to check the connectivity from cell-to-cell, with they will do.
- George reported on the SiPM work. Two new results will be posted to the portal shortly. Conclusions from the Phase I tests are