Difference between revisions of "FADC Data Format Mar 11, 2014"
From GlueXWiki
(Created page with "= Location and Time = '''Room:''' CC F326-327 '''Time:''' 1:30pm-2:30pm = Remote Connection = '''ESNet:''' 8542553 (if problems, call phone in conference room: 757-269-6460) ...") |
m (Text replacement - "http://argus.phys.uregina.ca/cgi-bin/private" to "https://halldweb.jlab.org/doc-private") |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 14: | Line 14: | ||
* Status of FADC125 Firmware | * Status of FADC125 Firmware | ||
* [http://www.jlab.org/Hall-D/detector/fdc/FDC_pulse_data_format.pptx FDC_pulse_data_format] | * [http://www.jlab.org/Hall-D/detector/fdc/FDC_pulse_data_format.pptx FDC_pulse_data_format] | ||
− | * [[ | + | * [[CDC_algo|CMU timing algorithm - details updated]] |
− | * [[CDC_readout_requirements|CDC readout needs]] | + | * [[CDC_readout_requirements|CDC readout needs]] [[CDC_garfield_calcs|Garfield calcs]] |
− | * [ | + | * [https://halldweb.jlab.org/doc-private/DocDB/ShowDocument?docid=2274 fADC125 Data Format Specification Document] |
=Minutes= | =Minutes= | ||
− | Attendees: '' | + | Attendees: ''Naomi J., Fernando B., Cody D., David L., Beni Z.'' |
+ | |||
+ | * Firmware status | ||
+ | ** 11 crates in hall with firmware that reads data in raw form | ||
+ | ** Firmware uploads are now done completely over ethernet+VME (no longer need to pull out module) | ||
+ | ** Cody has been helping Beni track down specific issues with individual modules (e.g. missing bits) in FDC | ||
+ | *** fast readout in raw mode is first priority | ||
+ | ** Cody is also working on procurement of additional f250 modules | ||
+ | ** F125 algorithm is first priority though | ||
+ | * Only one CDC crate is currently in the hall | ||
+ | ** FDC will be moved into solenoid this week | ||
+ | ** CDC will be moved into hall next week | ||
+ | *** No testing of CDC will be done before then | ||
+ | *** It will be 2 or more weeks before CDC is connected for readout | ||
+ | ** Beni will have checked all FDC channels by this evening (not all will be working though, but he'll have a list of ones with issues) | ||
+ | ** There was some more discussion on the expected timing resolution of the CDC with the new and old algorithms | ||
+ | *** Fernando noted that even the old algorithm is within design specs. |
Latest revision as of 16:53, 24 February 2017
Location and Time
Room: CC F326-327
Time: 1:30pm-2:30pm
Remote Connection
ESNet: 8542553
(if problems, call phone in conference room: 757-269-6460)
Agenda
- Previous meeting (Feb. 25, 2014)
- Status of FADC125 Firmware
- FDC_pulse_data_format
- CMU timing algorithm - details updated
- CDC readout needs Garfield calcs
- fADC125 Data Format Specification Document
Minutes
Attendees: Naomi J., Fernando B., Cody D., David L., Beni Z.
- Firmware status
- 11 crates in hall with firmware that reads data in raw form
- Firmware uploads are now done completely over ethernet+VME (no longer need to pull out module)
- Cody has been helping Beni track down specific issues with individual modules (e.g. missing bits) in FDC
- fast readout in raw mode is first priority
- Cody is also working on procurement of additional f250 modules
- F125 algorithm is first priority though
- Only one CDC crate is currently in the hall
- FDC will be moved into solenoid this week
- CDC will be moved into hall next week
- No testing of CDC will be done before then
- It will be 2 or more weeks before CDC is connected for readout
- Beni will have checked all FDC channels by this evening (not all will be working though, but he'll have a list of ones with issues)
- There was some more discussion on the expected timing resolution of the CDC with the new and old algorithms
- Fernando noted that even the old algorithm is within design specs.