Kuraray Fiber tests

The following fibers from Kuraray have been tested for light output with a Sr90 source.

  • BLUE
    1. 81 MC lot:0801/103
  position     #photo-electrons
  =============================
   165cm        3.7  +/- 0.08
    65cm        5.1  +/- 0.2
   194cm        3.2  +/- 0.05 

  => Attenuation length L = 300cm
    1. 78 MC lot:0801/104
  position     #photo-electrons
  =============================
   194cm         3.9 +/- 0.07
    94cm         5.97+/- 0.27 
    61cm         6.99+/- 0.31

  => Attenuation length L = 230cm
  • GEEN
    1. 3HF MC lot:0801/105
  position     #photo-electrons
  =============================
    65cm        2.3  +/- 0.03
   165cm        1.95 +/- 0.01
 
  => Attenuation length L = 523 cm