Difference between revisions of "Meetings-2-4-2021"
(→Agenda) |
|||
Line 4: | Line 4: | ||
Thu 2/4/2021 2pm | Thu 2/4/2021 2pm | ||
= Agenda = | = Agenda = | ||
− | |||
#* [http://www.jlab.org/Hall-D/detector/trd/Jpsi_tracking_Feb4.pdf chi^2 comparison] | #* [http://www.jlab.org/Hall-D/detector/trd/Jpsi_tracking_Feb4.pdf chi^2 comparison] | ||
− | |||
− | |||
− | |||
#** Tuning of broken wires in [https://halldweb.jlab.org/talks/2021/FDC_Efficiency/FDC_Eff_2017_G4.gif MC], comparison with [https://halldweb.jlab.org/talks/2021/FDC_Efficiency/FDC_Eff_2017_Data.gif Spring 2017 Data] | #** Tuning of broken wires in [https://halldweb.jlab.org/talks/2021/FDC_Efficiency/FDC_Eff_2017_G4.gif MC], comparison with [https://halldweb.jlab.org/talks/2021/FDC_Efficiency/FDC_Eff_2017_Data.gif Spring 2017 Data] | ||
#** Kaon efficiencies (Chandra)[https://halldweb.jlab.org/DocDB/0049/004900/001/KPlusEfficiencyStudiesChandra.pdf] | #** Kaon efficiencies (Chandra)[https://halldweb.jlab.org/DocDB/0049/004900/001/KPlusEfficiencyStudiesChandra.pdf] | ||
− | |||
#* [http://www.jlab.org/Hall-D/detector/trd/GEM_TRD_tracking_Feb4.pdf gas analysis and padGEM studies] | #* [http://www.jlab.org/Hall-D/detector/trd/GEM_TRD_tracking_Feb4.pdf gas analysis and padGEM studies] | ||
# Other - collaboration meeting | # Other - collaboration meeting | ||
+ | |||
+ | = Minutes = | ||
+ | # Other: No tracking talk on the collaboration meeting. Some tracking related topics will be discussed in other talks. | ||
+ | # Tracking updates | ||
+ | Discussing the track-fitting quality, chi^2/ndf, vs theta for 2020, compared to the previous running periods. The deterioration for theta>10 deg should be studied with high rate reactions (Alex with rho) or just inclusively (Sean). Alex: many changes have been done in the tracking software for the 2020 production, need to evaluate their effect on the tracking quality. | ||
+ | # Detector-related analysis | ||
+ | #* CDC | ||
+ | #* FDC | ||
+ | # GEM-TRD | ||
+ | We finished with the CDC gas tests: no Oxygen at 100ppm level, so CDC is very gas tight. The Oxygen we see with the gas chromatograph most likely comes from the tubing at/around the bubblers. Will restore the gas in the CDC and do the same tests with the FDC. | ||
+ | Kondo performed analysis of the resolution of the padGEM (1x1 cm^2 pads) for different pad patterns: found significant improvement (~300 microns) when you have 3x3 pads above threshold. |
Revision as of 16:45, 4 February 2021
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Thu 2/4/2021 2pm
Agenda
- chi^2 comparison
- Tuning of broken wires in MC, comparison with Spring 2017 Data
- Kaon efficiencies (Chandra)[2]
- gas analysis and padGEM studies
- chi^2 comparison
- Other - collaboration meeting
Minutes
- Other: No tracking talk on the collaboration meeting. Some tracking related topics will be discussed in other talks.
- Tracking updates
Discussing the track-fitting quality, chi^2/ndf, vs theta for 2020, compared to the previous running periods. The deterioration for theta>10 deg should be studied with high rate reactions (Alex with rho) or just inclusively (Sean). Alex: many changes have been done in the tracking software for the 2020 production, need to evaluate their effect on the tracking quality.
- Detector-related analysis
- CDC
- FDC
- GEM-TRD
We finished with the CDC gas tests: no Oxygen at 100ppm level, so CDC is very gas tight. The Oxygen we see with the gas chromatograph most likely comes from the tubing at/around the bubblers. Will restore the gas in the CDC and do the same tests with the FDC. Kondo performed analysis of the resolution of the padGEM (1x1 cm^2 pads) for different pad patterns: found significant improvement (~300 microns) when you have 3x3 pads above threshold.