Difference between revisions of "Meetings-2-4-2021"
From GlueXWiki
(→Minutes) |
|||
Line 12: | Line 12: | ||
= Minutes = | = Minutes = | ||
# Other: No tracking talk on the collaboration meeting. Some tracking related topics will be discussed in other talks. | # Other: No tracking talk on the collaboration meeting. Some tracking related topics will be discussed in other talks. | ||
− | # Tracking updates | + | # Tracking updates: Discussing the track-fitting quality, chi^2/ndf, vs theta for 2020, compared to the previous running periods. The deterioration for theta>10 deg should be studied with high rate reactions (Alex with rho) or just inclusively (Sean). Alex: many changes have been done in the tracking software for the 2020 production, need to evaluate their effect on the tracking quality. |
− | Discussing the track-fitting quality, chi^2/ndf, vs theta for 2020, compared to the previous running periods. The deterioration for theta>10 deg should be studied with high rate reactions (Alex with rho) or just inclusively (Sean). Alex: many changes have been done in the tracking software for the 2020 production, need to evaluate their effect on the tracking quality. | + | |
# Detector-related analysis | # Detector-related analysis | ||
#* CDC | #* CDC | ||
#* FDC | #* FDC | ||
− | # GEM-TRD | + | # GEM-TRD: We finished with the CDC gas tests: no Oxygen at 100ppm level, so CDC is very gas tight. The Oxygen we see with the gas chromatograph most likely comes from the tubing at/around the bubblers. Will restore the gas in the CDC and do the same tests with the FDC. |
− | We finished with the CDC gas tests: no Oxygen at 100ppm level, so CDC is very gas tight. The Oxygen we see with the gas chromatograph most likely comes from the tubing at/around the bubblers. Will restore the gas in the CDC and do the same tests with the FDC. | + | |
Kondo performed analysis of the resolution of the padGEM (1x1 cm^2 pads) for different pad patterns: found significant improvement (~300 microns) when you have 3x3 pads above threshold. | Kondo performed analysis of the resolution of the padGEM (1x1 cm^2 pads) for different pad patterns: found significant improvement (~300 microns) when you have 3x3 pads above threshold. |
Revision as of 16:46, 4 February 2021
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Thu 2/4/2021 2pm
Agenda
- chi^2 comparison
- Tuning of broken wires in MC, comparison with Spring 2017 Data
- Kaon efficiencies (Chandra)[2]
- gas analysis and padGEM studies
- chi^2 comparison
- Other - collaboration meeting
Minutes
- Other: No tracking talk on the collaboration meeting. Some tracking related topics will be discussed in other talks.
- Tracking updates: Discussing the track-fitting quality, chi^2/ndf, vs theta for 2020, compared to the previous running periods. The deterioration for theta>10 deg should be studied with high rate reactions (Alex with rho) or just inclusively (Sean). Alex: many changes have been done in the tracking software for the 2020 production, need to evaluate their effect on the tracking quality.
- Detector-related analysis
- CDC
- FDC
- GEM-TRD: We finished with the CDC gas tests: no Oxygen at 100ppm level, so CDC is very gas tight. The Oxygen we see with the gas chromatograph most likely comes from the tubing at/around the bubblers. Will restore the gas in the CDC and do the same tests with the FDC.
Kondo performed analysis of the resolution of the padGEM (1x1 cm^2 pads) for different pad patterns: found significant improvement (~300 microns) when you have 3x3 pads above threshold.