Difference between revisions of "Minutes-8-11-2016"
(→Agenda) |
|||
(14 intermediate revisions by 4 users not shown) | |||
Line 13: | Line 13: | ||
# Detector updates | # Detector updates | ||
#* CDC update (Naomi/Mike/Beni) | #* CDC update (Naomi/Mike/Beni) | ||
− | #** CDC thermocouple module switch (Naomi) | + | #** CDC thermocouple module switch (Naomi) [https://logbooks.jlab.org/entry/3412256 logbook entry] |
#* FDC update (Simon/Lubomir/Alex) | #* FDC update (Simon/Lubomir/Alex) | ||
− | #** Particle gun MC: momentum resolution comparison with/without using FDC drift times: | + | #** Particle gun MC: momentum resolution comparison with/without using FDC drift times (Simon): |
− | [[File:dp_5deg_comp.gif]] | + | #** [[File:dp_5deg_comp.gif]][[File:dp_p_10deg_comp.gif]] |
+ | #** RD: [https://halldweb.jlab.org/wiki/images/d/dc/FDC_Improvements.pdf Effect on Efficiency] (Alex A.) | ||
+ | #** CDC and FDC tracks with GENFIT examples: [http://www.jlab.org/Hall-D/detector/fdc/genfit/tr48_zy2.png track 48 zy], [http://www.jlab.org/Hall-D/detector/fdc/genfit/tr48_xy.png track 48 xy], [http://www.jlab.org/Hall-D/detector/fdc/genfit/tr45_zy.png track 45 zy], [http://www.jlab.org/Hall-D/detector/fdc/genfit/tr45_xy.png track 45 xy], [http://www.jlab.org/Hall-D/detector/fdc/genfit/tr42_zy.png track 42 zy], [http://www.jlab.org/Hall-D/detector/fdc/genfit/tr42_xy.png track 42 xy] (Lubomir) | ||
# NIM Papers | # NIM Papers | ||
#* svn ls https://halldsvn.jlab.org/repos/trunk/publications/GlueXCDC | #* svn ls https://halldsvn.jlab.org/repos/trunk/publications/GlueXCDC | ||
#* svn ls https://halldsvn.jlab.org/repos/trunk/publications/GlueXFDC | #* svn ls https://halldsvn.jlab.org/repos/trunk/publications/GlueXFDC | ||
− | # fADC125 meeting (Naomi, Cody, Beni) | + | # fADC125 meeting (Naomi, Cody, Beni) [[FA125_chip_occupancy|fa125 occupancy (corrected)(Beni was right)]] |
# Other | # Other | ||
− | |||
− | |||
= Minutes = | = Minutes = | ||
− | Participants: Sean (NU), | + | Participants: Sean (NU), Naomi, Curtis (CMU) Eugene, Chris, Luke, Beni, Alexander A., Simon, Sergey, and Lubomir (JLab). |
== CDC == | == CDC == | ||
− | - | + | - Naomi found a problem with the thermocouple that monitors the CDC temperature - see the log entry above. |
− | |||
− | |||
== FDC == | == FDC == | ||
+ | - Simon used simulations to demonstrate the advantage of adding the drift time information to the FDC track reconstruction - momentum resolution improves by a factor of sqrt(2) at high momenta. At low momenta multiple scattering dominates - see plots above. Can't wait to see the same improvement with real data. | ||
+ | |||
+ | - Alex A. showed plots with improved FDC (pseudo)hit efficiency in two stages, now it is close to 90%. When using the FDC drift time information there is a gap at small drift distances, probably these are excluded for the tracking? | ||
+ | |||
+ | - Lubomir showed tracks trough both CDC and FDC, taken from the CDC track hit objects (with the standard Hall D soft) and reconstructed with genfit. The feature that we don't understand is the fact that we often don't see hits in the CDC where we expect to have from extrapolating the FDC track to that region. | ||
+ | |||
+ | == fADC125 == | ||
− | -- | + | - Naomi studied the occupancy of the f125 chip by chip - see the above link for plots and tables. The chips with high occupancy in the FDC can be correlated with long strips just next to the beam, or noisy channels. |
Latest revision as of 14:46, 31 August 2016
August 11, 2016 Drift Chamber meeting
Connection
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
Headline text
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Agenda
- Detector updates
- CDC update (Naomi/Mike/Beni)
- CDC thermocouple module switch (Naomi) logbook entry
- FDC update (Simon/Lubomir/Alex)
- Particle gun MC: momentum resolution comparison with/without using FDC drift times (Simon):
-
- RD: Effect on Efficiency (Alex A.)
- CDC and FDC tracks with GENFIT examples: track 48 zy, track 48 xy, track 45 zy, track 45 xy, track 42 zy, track 42 xy (Lubomir)
- CDC update (Naomi/Mike/Beni)
- NIM Papers
- fADC125 meeting (Naomi, Cody, Beni) fa125 occupancy (corrected)(Beni was right)
- Other
Minutes
Participants: Sean (NU), Naomi, Curtis (CMU) Eugene, Chris, Luke, Beni, Alexander A., Simon, Sergey, and Lubomir (JLab).
CDC
- Naomi found a problem with the thermocouple that monitors the CDC temperature - see the log entry above.
FDC
- Simon used simulations to demonstrate the advantage of adding the drift time information to the FDC track reconstruction - momentum resolution improves by a factor of sqrt(2) at high momenta. At low momenta multiple scattering dominates - see plots above. Can't wait to see the same improvement with real data.
- Alex A. showed plots with improved FDC (pseudo)hit efficiency in two stages, now it is close to 90%. When using the FDC drift time information there is a gap at small drift distances, probably these are excluded for the tracking?
- Lubomir showed tracks trough both CDC and FDC, taken from the CDC track hit objects (with the standard Hall D soft) and reconstructed with genfit. The feature that we don't understand is the fact that we often don't see hits in the CDC where we expect to have from extrapolating the FDC track to that region.
fADC125
- Naomi studied the occupancy of the f125 chip by chip - see the above link for plots and tables. The chips with high occupancy in the FDC can be correlated with long strips just next to the beam, or noisy channels.