Participants: Sean (NU), Mike (CMU) Eugene, Cody, Luke, Beni, Alexander A., Simon, and Lubomir (JLab).
+
Participants: Sean (NU), Curtis, Naomi (CMU) Paul, Eugene, Beni, Alexander A., Simon, and Lubomir (JLab).
  
== CDC ==
+
== Tracking ==
  
- In the analyses meeting Mike reported already [https://halldweb.jlab.org/wiki/images/b/b5/MStaibCDCEfficiencyS16.pdf his studies] on the CDC efficiency.
+
- Most of the meeting was about Paul's presentation of the tracking efficiencies by studying different reactions with missing particle - see complete presentation linked.  
  
- Beni: Nick and Chris are cleaning/replacing the CDC HVB that had some issues during the last run due to some dust on them. We discussed possible origins of this dust: coming from the cooling tubes, air, or sucked by the magnetic field.
+
- Lubomir summarized his results on the FDC resolutions with magnetic field. He also started including CDC in the tracking with GENFIT.
 
   
 
   
== FDC ==
+
== CDC ==
 
+
  
-->
+
- To calibrate CDC with source we need f125 self-triggering.

Revision as of 19:45, 18 November 2016

September 1, 2016 Drift Chamber meeting

Connection

  1. Instructions for Bluejeans meeting connection
  2. Meeting ID: 290664653

Headline text

  1. To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.

Agenda

  1. Tracking
  2. Detector update
    • CDC (Naomi/Mike/Beni)
      • gain calibration with source?
    • FDC (Lubomir)
  3. fADC125 meeting (Naomi, Cody, Beni)
  4. Other

Minutes

Participants: Sean (NU), Curtis, Naomi (CMU) Paul, Eugene, Beni, Alexander A., Simon, and Lubomir (JLab).

Tracking

- Most of the meeting was about Paul's presentation of the tracking efficiencies by studying different reactions with missing particle - see complete presentation linked.

- Lubomir summarized his results on the FDC resolutions with magnetic field. He also started including CDC in the tracking with GENFIT.

CDC

- To calibrate CDC with source we need f125 self-triggering.