Line 26: Line 26:
 
|}
 
|}
  
 +
 +
# Details: [http://www.jlab.org/Hall-D/software/wiki/index.php/Dec_06%2C_2010_Calibration/Monitoring Minutes/notes from December 6, 2010]
 
# Comment: Time (and temperature) stability most important.
 
# Comment: Time (and temperature) stability most important.
# Comment: Option of delivering a range of light intensities important (e.g. using various filter settings).
+
# Comment: Option of delivering a range of light intensities important (e.g. using various filter settings). Athens: test stability of LEDs at low output (near threshold) to see if this can be used as an additional check point in our monitoring.
# Comment from Werner: The flexibility in the use of the LED would be very useful for the start counter. Christina: Still need to test stability.
+
# Comment: The flexibility in the use of the LED would be very useful for the start counter.
# Questions to Matt: What uniformity could one expect from the plexiglass input system? How many fibers were used to pulse the plexiglass, i.e. how often were they spaced?
+
# Comment: Matt drew attention to an  [http://physics.indiana.edu/~ptsmith/pulseled/ LED pulser by Paul Smith] which might be a useful reference.
+

Revision as of 18:07, 8 December 2010

DRAFT Table of System Requirements and Comparison
Characteristic LED/fibre LED/wire
Dead/alive or on/off yes yes
Timing check/offset yes yes
Relative gain check yes yes
Linearity check low end (a few times one LED) only low end (a few times one LED) only
Temperature stability yes, sensors in box sensors in areal spread?
Tower row flashing yes, multiplexer yes, multiplexer
Simultaneously flash both ends no solution yet no solution yet
Location of LEDs input Boxes at outer edge of each module, fibres LED+board on light guide, LPCM in rack
Geometrical constraints mechanical/fragility/replacement are serious concerns none; easy to install
R&D done Some, solution not preferred Extensive, mature solution exists
Cost Not costed quotation exists (getting stale)


  1. Details: Minutes/notes from December 6, 2010
  2. Comment: Time (and temperature) stability most important.
  3. Comment: Option of delivering a range of light intensities important (e.g. using various filter settings). Athens: test stability of LEDs at low output (near threshold) to see if this can be used as an additional check point in our monitoring.
  4. Comment: The flexibility in the use of the LED would be very useful for the start counter.