# Details: [http://www.jlab.org/Hall-D/software/wiki/index.php/Dec_06%2C_2010_Calibration/Monitoring Minutes/notes from December 6, 2010]
 
# Details: [http://www.jlab.org/Hall-D/software/wiki/index.php/Dec_06%2C_2010_Calibration/Monitoring Minutes/notes from December 6, 2010]
# Comment: Time (and temperature) stability most important.
+
# Comment: time and temperature stability of system is very important.
# Comment: Option of delivering a range of light intensities important (e.g. using various filter settings). Athens: test stability of LEDs at low output (near threshold) to see if this can be used as an additional check point in our monitoring.
+
# Comment: Option of delivering a range of light intensities important (e.g. using various filter settings). Athens will test stability of LEDs at low output (near threshold) to see if this can be used as an additional check point in our monitoring.  Double LED system (one UV and one blue) per light guide will be investigated.
# Comment: The flexibility in the use of the LED would be very useful for the start counter.
+
# Comment: LED system could be very useful for the Start Counter.

Revision as of 18:09, 8 December 2010

DRAFT Table of System Requirements and Comparison
Characteristic LED/fibre LED/wire
Dead/alive or on/off yes yes
Timing check/offset yes yes
Relative gain check yes yes
Linearity check low end (a few times one LED) only low end (a few times one LED) only
Temperature stability yes, sensors in box sensors in areal spread?
Tower row flashing yes, multiplexer yes, multiplexer
Simultaneously flash both ends no solution yet no solution yet
Location of LEDs input Boxes at outer edge of each module, fibres LED+board on light guide, LPCM in rack
Geometrical constraints mechanical/fragility/replacement are serious concerns none; easy to install
R&D done Some, solution not preferred Extensive, mature solution exists
Cost Not costed quotation exists (getting stale)
  1. Details: Minutes/notes from December 6, 2010
  2. Comment: time and temperature stability of system is very important.
  3. Comment: Option of delivering a range of light intensities important (e.g. using various filter settings). Athens will test stability of LEDs at low output (near threshold) to see if this can be used as an additional check point in our monitoring. Double LED system (one UV and one blue) per light guide will be investigated.
  4. Comment: LED system could be very useful for the Start Counter.