Noise studies - scope traces | Noise studies - scope traces | ||
+ | |||
+ | These are for ch16, which shows the largest amount of 4MHz pickup. | ||
{| border="1" cellpadding="2" | {| border="1" cellpadding="2" | ||
Line 6: | Line 8: | ||
|} | |} | ||
− | + | After connecting the preamp ground to the preamp end of the cable shielding | |
{| border="1" cellpadding="2" | {| border="1" cellpadding="2" | ||
|width="400pt"|[[Image:outside_cage_pre_ground_to_shield.jpg|thumb|none|400px|Noise - cable shield connected to preamp ground, 1950V, 90/10 premix]] | |width="400pt"|[[Image:outside_cage_pre_ground_to_shield.jpg|thumb|none|400px|Noise - cable shield connected to preamp ground, 1950V, 90/10 premix]] | ||
|width="400pt"|[[Image:outside_cage_pre_ground_to_shield_4MHz.jpg|thumb|none|400px|Noise - zoom on 4MHz - cable shield connected to preamp ground, 1950V, 90/10 premix]] | |width="400pt"|[[Image:outside_cage_pre_ground_to_shield_4MHz.jpg|thumb|none|400px|Noise - zoom on 4MHz - cable shield connected to preamp ground, 1950V, 90/10 premix]] | ||
|} | |} |
Revision as of 14:14, 27 July 2010
Noise studies - scope traces
These are for ch16, which shows the largest amount of 4MHz pickup.
After connecting the preamp ground to the preamp end of the cable shielding