Roadmap toward a decision for Bcal Readout

From GlueXWiki
Revision as of 09:45, 5 February 2009 by Elton (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Roadmap toward a decision for Bcal Readout

  1. Technical specifications, already outlined in GlueX-doc-795
  2. Geometry, especially related to acceptance gap between Bcal and Fcal. Detailed plan should be developed.
    • Light guides and inactive material is different for the two options. We need to simulate the effect of each
    • Precise configuration of light guides for FM pmts on the upstream end, where the field at the end of the Bcal exceeds 0.5 T. See light guides studies in GlueX-doc-1077
    • Detail description of cables and electronics on each detector
  3. Granularity.
    • Optimization of distribution between inner and outer detectors
    • Which detectors should have discriminators and TDCs
    • Study of signal splitting, choice of discriminator - has an impact on number of cables.
  4. Resolution
  5. Detailed B-field plots including dependence on B-field components
  6. Dynamic range required, especially for near pmt/small angle showers.

Silicon PM

Fine Mesh PMT

Light Guides