Difference between revisions of "SiPM Radiation Hardness Test"

From GlueXWiki
Jump to: navigation, search
m (2010 Mar 17)
m (2010 Mar 17)
Line 34: Line 34:
  
 
=== 2010 Mar 17 ===
 
=== 2010 Mar 17 ===
 +
 
* photos of SiPM test setup
 
* photos of SiPM test setup
 
[[Image:SiPM_test_close.jpg|thumb|Close view of SiPM test setup]]
 
[[Image:SiPM_test_close.jpg|thumb|Close view of SiPM test setup]]
[[Image:SiPM_test_overall.jpg|right|700px]]
+
[[Image:SiPM_test_overall.jpg|thumb|Location of the SiPM Box]]
[[Image:SiPM_test_hall.jpg|right|700px]]
+
[[Image:SiPM_test_hall.jpg|thumb|Distance between SiPM and Hall A Target]]
  
 
=== 2010 Mar 18 ===
 
=== 2010 Mar 18 ===

Revision as of 12:20, 18 March 2010

SiPM Radiation Hardness Test in Hall A

Test Plan

System Diagram

Device List

  • Control Computer: transversity.jlab.org: (129.57.164.28)
  • GPIB over IP: GPIB-ENET/100: agpib.jlab.org (129.57.192.73)
  • Serial Port Server: ESP904: portservha50.jlab.org (129.57.192.78)
  • USB over IP: AnywhereUSB/5: ausb.jlab.org (129.57.192.75)
  • Oscilliscope: TDS3034: dosci.jlab.org (129.57.192.77)
  • Power Outlet: APC Outlet Control: hlauser:hlauser@hareboot12.jlab.org (129.57.192.76)
    • Outlet 1: Pulse Generator
    • Outlet 2: Temperature Box
    • Outlet 3: Oscilliscope
    • Outlet 4: GPIB over IP
    • Outlet 5: Power Supply for Hamamatsu Unit
    • Outlet 6: Power Supply for SensL Unit
    • Outlet 7: Picoamp Meter
    • Outlet 8: Serial Port Server
  • USB to Serial HUB: ComHUB
    • Serial 1: Power Supply for Hamamatsu Unit
    • Serial 2: Power Supply for SensL Unit
    • Serial 3: Oscilliscope
    • Serial 4: Temperature Box
  • Picoamp Meter x2: Keithley-485 (GPIB)
    • GPIB Address: 1 (Hamamatsu); 2 (SensL)
  • Pulse Generator: HP-8116A (GPIB)
    • GPIB Address: 4
  • Power Supply x2: B&K-1787B (RS232)
  • Temperature Meter: CN77544 (RS232)

2010 Mar 17

  • photos of SiPM test setup
Close view of SiPM test setup
Location of the SiPM Box
Distance between SiPM and Hall A Target

2010 Mar 18

  • Hamamatsu SiPM Draw Current vs Bias Voltage
  • SensL SiPM Draw Current vs Bias Voltage
  • Signals on Oscilliscope with 70.5V on Hamamatsu and 28.5V on SensL
Hamamatsu SiPM Draw Current vs Bias Voltage
SensL SiPM Draw Current vs Bias Voltage