SiPM Radiation Hardness Test in Hall A

Test Plan

System Diagram

Device List

  • Control Computer: transversity.jlab.org: (129.57.164.28)
  • GPIB over IP: GPIB-ENET/100: agpib.jlab.org (129.57.192.73)
  • Serial Port Server: ESP904: portservha50.jlab.org (129.57.192.78)
  • USB over IP: AnywhereUSB/5: ausb.jlab.org (129.57.192.75)
  • Oscilliscope: TDS3034: dosci.jlab.org (129.57.192.77)
  • Power Outlet: APC Outlet Control: hlauser:hlauser@hareboot12.jlab.org (129.57.192.76)
    • Outlet 1: Pulse Generator
    • Outlet 2: Temperature Box
    • Outlet 3: Oscilliscope
    • Outlet 4: GPIB over IP
    • Outlet 5: Power Supply for Hamamatsu Unit
    • Outlet 6: Power Supply for SensL Unit
    • Outlet 7: Picoamp Meter
    • Outlet 8: Serial Port Server
  • USB to Serial HUB: ComHUB
    • Serial 1: Power Supply for Hamamatsu Unit
    • Serial 2: Power Supply for SensL Unit
    • Serial 3: Oscilliscope
    • Serial 4: Temperature Box
  • Picoamp Meter x2: Keithley-485 (GPIB)
    • GPIB Address: 1 (Hamamatsu); 2 (SensL)
  • Pulse Generator: HP-8116A (GPIB)
    • GPIB Address: 4
  • Power Supply x2: B&K-1787B (RS232)
  • Temperature Meter: CN77544 (RS232)

2010 Mar 17

Close view of SiPM test setup
Location of the SiPM Box
Distance between SiPM and Hall A Target
  • Photos of SiPM test setup.
  • All Hardware intrustruments have been connected.
  • The SiPM box is put on top of the cryo target parking support which is at about 135 degree to the left side of the beam and 20 meters away from the target.
  • The real time neutron counter is put right next to the SiPM.

2010 Mar 18

  • Hamamatsu SiPM Draw Current vs Bias Voltage
  • SensL SiPM Draw Current vs Bias Voltage
  • Signals on Oscilliscope with 70.5V on Hamamatsu and 28.5V on SensL
Hamamatsu SiPM Draw Current vs Bias Voltage
SensL SiPM Draw Current vs Bias Voltage
Signals on Oscilliscope with 70.5V on Hamamatsu and 28.5V on SensL