GTP Trigger Summary Table

Mask Condition FCAL rings masked Prescale Run Start Run End Date Range Log entry
FCAL-BCAL
000000001 25*FCAL + 1*BCAL > 45000 && FCAL > 200 2 None 30274 31057 Full Run Period
BCAL
000000100 BCAL > 54000 N/A None 30274 31057 Full Run Period
PS
000001000 PSC Coincidence N/A None 30274 31057 Full Run Period
FCAL-BCAL-ST
010000000 25*FCAL + 1*BCAL > 45000 && FCAL > 200 && # ST hit > 0 2 None 31049 31057 3/9/17 - EOR 3465388 3467007
ST-TAGH Minimum Bias
100000000 ST hit and TAGH hit with roughly 9.8 < Eγ < 10.2 N/A None 31049 31057 3/9/17 - EOR 3465388 3467007

Front Panel Trigger Summary Table

The 4 Front Panel triggers listed here were included in the production configuration for the full Spring 2017 Run Period.

FP Input FP Bit
FCAL LED 3
BCAL LED Upstream 9
BCAL LED Downstream 10
Random pulser 12

Monitoring Configuration File Changes

The configuration files (e.g. FCAL_BCAL_PS_m9.conf) are stored in RCDB for each run, and contain all the relevant configuration variables. This link: Configuration File Changes: Spring 2018 provides a list of when the standard production configuration file changed (according to RCDB), and the difference with the previous configuration file. The specific run numbers for various trigger changes in the table above are derived from these configuration files.

Summary of Configuration Changes

Parameter Changed Run Start Comment
CDC time window delay 41482 Move hits closer to the beginning of the time window to reduce "shadowing" of signal hits