The Effect of the CDC/FDC Gap on Charged Particle Resolution in GlueX
Document #:
GlueX-doc-1132-v1
Document type:
Hall D Note
Submitted by:
Mark Ito
Updated by:
Mark Ito
Document Created:
16 Oct 2008, 12:07
Contents Revised:
16 Oct 2008, 12:07
Metadata Revised:
16 Oct 2008, 12:07
Viewable by:
Public document
Modifiable by:
Same as Viewable by
Quick Links:
Latest Version
Other Versions:
GlueX-doc-1132-v3
26 May 2009, 09:26
GlueX-doc-1132-v2
16 Oct 2008, 13:24
Abstract:
This note presents a study of the effect on resolution of varying the spacing between the central drift chamber and the forward drift chamber in the GlueX detector.