Timing characteristics of two time-of-flight scintillation counters were studied using particle beams at the IHEP (Protvino) accelerator. The bars were 2 m long and had a cross-section of 2.5 x 6.0cm^2. Each bar was viewed from both ends by XP2020 photomultipliers. A time resolution better than 40 ps was achieved.