Difference between revisions of "Tune Electron Beam"
From Hall D Ops Wiki
(Created page with "__TOC__ ==Tune Electron Beam== # Goal: Get electron beam to the dump in the tagger hall. # Responsibility: Accelerator, HallD, RadCon. # Conditions: #* Tagger hall equipment r...") |
(→Tune Electron Beam) |
||
Line 1: | Line 1: | ||
__TOC__ | __TOC__ | ||
+ | [[Fall 2014 Commissioning Plan]] | ||
==Tune Electron Beam== | ==Tune Electron Beam== | ||
# Goal: Get electron beam to the dump in the tagger hall. | # Goal: Get electron beam to the dump in the tagger hall. | ||
Line 12: | Line 13: | ||
#* Check radiation levels in the tagger hall. | #* Check radiation levels in the tagger hall. | ||
#* Check for photons and radiation levels in the collimator cave. | #* Check for photons and radiation levels in the collimator cave. | ||
+ | |||
==[[Tune Photon Beam]]== | ==[[Tune Photon Beam]]== | ||
==[[One Week Pause in Running]]== | ==[[One Week Pause in Running]]== |
Revision as of 09:42, 2 July 2014
Contents
Tune Electron Beam
- Goal: Get electron beam to the dump in the tagger hall.
- Responsibility: Accelerator, HallD, RadCon.
- Conditions:
- Tagger hall equipment removed or shielded. This includes the microscope (TAGM) and the electronics.
- Pulsed beam may be used.
- No radiator installed.
- Collimator blocks the photon beamline to Hall D.
- Activities:
- Tune beam to the dump, check the beam specification.
- Check radiation levels in the tagger hall.
- Check for photons and radiation levels in the collimator cave.