Difference between revisions of "Tune Electron Beam"
From Hall D Ops Wiki
(→Tune Electron Beam) |
(→Tune Electron Beam) |
||
Line 3: | Line 3: | ||
==Tune Electron Beam== | ==Tune Electron Beam== | ||
− | # Goal: Get electron beam to the dump in the tagger hall. | + | # Expected duration: Approximately a few days. |
− | # Responsibility: Accelerator, HallD, RadCon. | + | # Goal: Get electron beam to the dump in the tagger hall with acceptable radiation levels. |
+ | # Responsibility: Main: Accelerator, support: HallD, RadCon. | ||
# Priority: High | # Priority: High | ||
# Conditions: | # Conditions: | ||
− | #* Tagger hall equipment removed | + | #* Tagger hall equipment removed. This includes the microscope (TAGM) and the electronics. |
− | #* | + | #* Hall D controlled quadrupoles turned off. |
+ | #* Initially [[https://halldweb1.jlab.org/wiki/index.php/Tune_mode pulsed beam]] will be used, then CW beam. | ||
#* No radiator installed. | #* No radiator installed. | ||
#* Collimator blocks the photon beamline to Hall D. | #* Collimator blocks the photon beamline to Hall D. | ||
+ | #* Backsplash detector (if available) installed at entrance of collimator cave. | ||
# Activities: | # Activities: | ||
− | #* Tune beam to the dump, check the beam | + | #* Tune beam to the dump, check the beam specifications (accelerator). |
− | #* Check radiation levels in the tagger hall. | + | #* Check radiation levels in the tagger hall (Hall D/RadCon). |
− | #* Check for photons and radiation levels in the collimator cave. | + | #* Check for photons (with backsplash detector) and radiation levels in the collimator cave (Hall D/RadCon). |
==[[Tune Photon Beam]]== | ==[[Tune Photon Beam]]== |
Revision as of 14:30, 16 July 2014
Contents
Main Page
Tune Electron Beam
- Expected duration: Approximately a few days.
- Goal: Get electron beam to the dump in the tagger hall with acceptable radiation levels.
- Responsibility: Main: Accelerator, support: HallD, RadCon.
- Priority: High
- Conditions:
- Tagger hall equipment removed. This includes the microscope (TAGM) and the electronics.
- Hall D controlled quadrupoles turned off.
- Initially [pulsed beam] will be used, then CW beam.
- No radiator installed.
- Collimator blocks the photon beamline to Hall D.
- Backsplash detector (if available) installed at entrance of collimator cave.
- Activities:
- Tune beam to the dump, check the beam specifications (accelerator).
- Check radiation levels in the tagger hall (Hall D/RadCon).
- Check for photons (with backsplash detector) and radiation levels in the collimator cave (Hall D/RadCon).