# Goal: Get electron beam to the dump in the tagger hall.
+
# Expected duration: Approximately a few days.
# Responsibility: Accelerator, HallD, RadCon.
+
# Goal: Get electron beam to the dump in the tagger hall with acceptable radiation levels.
 +
# Responsibility: Main: Accelerator, support: HallD, RadCon.
 
# Priority: High
 
# Priority: High
 
# Conditions:
 
# Conditions:
#* Tagger hall equipment removed or shielded. This includes the microscope (TAGM) and the electronics.
+
#* Tagger hall equipment removed. This includes the microscope (TAGM) and the electronics.
#* Pulsed beam may be used.
+
#* Hall D controlled quadrupoles turned off.
 +
#* Initially [[https://halldweb1.jlab.org/wiki/index.php/Tune_mode pulsed beam]] will be used, then CW beam.  
 
#* No radiator installed.
 
#* No radiator installed.
 
#* Collimator blocks the photon beamline to Hall D.
 
#* Collimator blocks the photon beamline to Hall D.
 +
#* Backsplash detector (if available) installed at entrance of collimator cave.
 
# Activities:
 
# Activities:
#* Tune beam to the dump, check the beam specification.
+
#* Tune beam to the dump, check the beam specifications (accelerator).
#* Check radiation levels in the tagger hall.
+
#* Check radiation levels in the tagger hall (Hall D/RadCon).
#* Check for photons and radiation levels in the collimator cave.
+
#* Check for photons (with backsplash detector) and radiation levels in the collimator cave (Hall D/RadCon).
  
 
==[[Tune Photon Beam]]==
 
==[[Tune Photon Beam]]==

Revision as of 15:30, 16 July 2014

Main Page

Tune Electron Beam

  1. Expected duration: Approximately a few days.
  2. Goal: Get electron beam to the dump in the tagger hall with acceptable radiation levels.
  3. Responsibility: Main: Accelerator, support: HallD, RadCon.
  4. Priority: High
  5. Conditions:
    • Tagger hall equipment removed. This includes the microscope (TAGM) and the electronics.
    • Hall D controlled quadrupoles turned off.
    • Initially [pulsed beam] will be used, then CW beam.
    • No radiator installed.
    • Collimator blocks the photon beamline to Hall D.
    • Backsplash detector (if available) installed at entrance of collimator cave.
  6. Activities:
    • Tune beam to the dump, check the beam specifications (accelerator).
    • Check radiation levels in the tagger hall (Hall D/RadCon).
    • Check for photons (with backsplash detector) and radiation levels in the collimator cave (Hall D/RadCon).