# No radiator | # No radiator | ||
# Hall D quadrupole magnet MQPAD00 turned off | # Hall D quadrupole magnet MQPAD00 turned off | ||
+ | # Hall D/Tagger Hall locked | ||
+ | # No shift workers in Hall D; experts from Hall D are involved with the radiation measurements | ||
* Activities: | * Activities: | ||
Line 30: | Line 32: | ||
# Check for photons (with the Profiler and Active Collimator) and radiation levels in the collimator cave (Hall D/RadCon). | # Check for photons (with the Profiler and Active Collimator) and radiation levels in the collimator cave (Hall D/RadCon). | ||
− | * Responsibility: Main: Accelerator | + | * Responsibility: Main: Accelerator; support: HallD, RadCon. |
==[[Tune Photon Beam]]== | ==[[Tune Photon Beam]]== |
Revision as of 16:44, 6 August 2014
Contents
Main Page
Tune Electron Beam
Tune Electron Beam
- Goal: provide a clean electron beam through the center of the beam aperture to the beam dump in the tagger hall with acceptable radiation levels.
- Priority: High
- Link to the accelerator test plan for electron beam commissioning (ATLIS)
- Expected duration Sept 29 - Oct 3 2014
- Prerequisites:
- Tagger microscope (TAGM) and all the crates with electronics should be removed from Hall D.
- Goniometer in the beam-open position. The goniometer will not be used during the 2014 run
- Amorphous radiator ladder equipped (HAPR included) and operational
- Beam lines under vacuum
- Tagger magnet operational
- Shielding walls installed
- Radiation monitors installed and operational
- Collimator block in the position between two holes, shielding the central area of the beam pipe
- Profiler counter installed in front of the collimator
- Conditions:
- Pulsed beam pulsed beam 4-10 µA (average 60-150 nA) for the beam tune
- CW beam 50-100 nA at the final stage of the procedure
- No radiator
- Hall D quadrupole magnet MQPAD00 turned off
- Hall D/Tagger Hall locked
- No shift workers in Hall D; experts from Hall D are involved with the radiation measurements
- Activities:
- Tune the pulsed beam to the dump, check the beam specifications, send the CW beam (accelerator).
- Check radiation levels in the tagger hall (Hall D/RadCon).
- Check for photons (with the Profiler and Active Collimator) and radiation levels in the collimator cave (Hall D/RadCon).
- Responsibility: Main: Accelerator; support: HallD, RadCon.