Difference between revisions of "Meetings-5-20-2021"
From GlueXWiki
(Created page with "# [https://halldweb.jlab.org/wiki/index.php/Connect_to_Bluejeans_Meetings Instructions for Bluejeans meeting connection] # Meeting ID: 290664653 # To join via a Web Browser, g...") |
(→Minutes) |
||
(15 intermediate revisions by 2 users not shown) | |||
Line 6: | Line 6: | ||
# Tracking | # Tracking | ||
# Detector related reports | # Detector related reports | ||
+ | ## [https://halldweb.jlab.org/wiki/images/0/01/20210520.pdf millepede Ks] | ||
#* FA125 | #* FA125 | ||
#* CDC | #* CDC | ||
− | |||
#* FDC | #* FDC | ||
− | |||
− | |||
− | |||
# GEM-TRD | # GEM-TRD | ||
+ | #* [http://www.jlab.org/Hall-D/detector/trd/IMG_5773.pdf test setup] | ||
# Other | # Other | ||
= Minutes = | = Minutes = | ||
# Tracking | # Tracking | ||
+ | #* Keigo added plugins/Alignment/MilleKs for Ks alignment [https://github.com/JeffersonLab/halld_recon/pull/526 Pull Request]. | ||
+ | #* [https://halldweb.jlab.org/wiki/images/a/a6/20210524_01.pdf Slides (updated parameters and residuals)] | ||
+ | #* I've noticed FDC t0 parameters are not fully optimized for these runs (30274 - 31507) .. | ||
+ | #* After applying MilleKs, wire residual distribution shows two peaks... --> SOLVED | ||
+ | #* [https://halldweb.jlab.org/wiki/images/b/b8/20210525.pdf Update MilleKs plugin (+ analyzer crash issue)] (25-May-2021) | ||
+ | #* [https://halldweb.jlab.org/wiki/images/2/26/Res_par_cmp.pdf residual & alignment parameters] (27-May-2021) | ||
+ | #** ccdb00.sqlite .. official CCDB (= mysql://ccdb_user@hallddb.jlab.org/ccdb) | ||
+ | #** ccdb01.sqlite .. MilleKs is applied (FDC t0 fixed) | ||
+ | #** ccdb02.sqlite .. MilleKs is applied (FDC t0 unfixed) | ||
# Detector related reports | # Detector related reports | ||
#* FA125 | #* FA125 |
Latest revision as of 11:42, 28 May 2021
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Thu 5/20/2021 2pm
Agenda
- Tracking
- Detector related reports
- FA125
- CDC
- FDC
- GEM-TRD
- Other
Minutes
- Tracking
- Keigo added plugins/Alignment/MilleKs for Ks alignment Pull Request.
- Slides (updated parameters and residuals)
- I've noticed FDC t0 parameters are not fully optimized for these runs (30274 - 31507) ..
- After applying MilleKs, wire residual distribution shows two peaks... --> SOLVED
- Update MilleKs plugin (+ analyzer crash issue) (25-May-2021)
- residual & alignment parameters (27-May-2021)
- ccdb00.sqlite .. official CCDB (= mysql://ccdb_user@hallddb.jlab.org/ccdb)
- ccdb01.sqlite .. MilleKs is applied (FDC t0 fixed)
- ccdb02.sqlite .. MilleKs is applied (FDC t0 unfixed)
- Detector related reports
- FA125
- CDC
- FDC
- GEM-TRD
- Other