Difference between revisions of "Minutes-8-20-2015"
From GlueXWiki
Line 21: | Line 21: | ||
= Minutes = | = Minutes = | ||
− | Participants: Curtis | + | Participants: Curtis, Mike (CMU), Fernando, Eugene, Luke, Beni, Dave, Nick, Simon, and Lubomir (JLab). |
== Detector performance document == | == Detector performance document == | ||
− | - | + | - Lubomir updated the document on the portal with one-and-a-half page about the FDC. Some discussions about the resolution plots there: cathode resolutions in x and y-direction very different. Tracking only doesn't explain this contradiction, since in x direction the wire resolution that also uses tracking reaches 150 microns, to be compared with the cathode y-resolution of about 200 microns. |
== CDC update == | == CDC update == | ||
Line 35: | Line 35: | ||
== Electronics == | == Electronics == | ||
− | - | + | - Nick showed pictures (logbook entry linked above) demonstrating the separation of the CDC broken wire. |
== FDC update == | == FDC update == |
Revision as of 17:19, 24 August 2015
August 20, 2015 Drift Chamber meeting
Connection
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Agenda
- Detector performance document GlueX-doc-2775,
- CDC update (Mike, Simon, Beni)
- FDC update (Luke,Lubomir)
- Electronics (Fernando, Chris, Nick)
- Engineering
- Other