Difference between revisions of "Short Term Run Plan"
(→timing problems) |
(→Shift leader) |
||
Line 16: | Line 16: | ||
Guidelines are at https://halldweb.jlab.org/hdops/wiki/index.php/Shift_Guidelines_for_Shift_Leader | Guidelines are at https://halldweb.jlab.org/hdops/wiki/index.php/Shift_Guidelines_for_Shift_Leader | ||
+ | |||
* Remember to include a separate '''list of the runs''' taken during the shift at the end of the summary (for example, see https://logbooks.jlab.org/entry/3926883) | * Remember to include a separate '''list of the runs''' taken during the shift at the end of the summary (for example, see https://logbooks.jlab.org/entry/3926883) | ||
− | * Remember to log the '''strip charts''' of beam current and position. | + | |
+ | * Remember to log the '''strip charts''' of beam current and position, see https://halldweb.jlab.org/hdops/wiki/index.php/Slow_Controls_Shift#MYA_Archiver | ||
+ | ** on a gluon machine type myaPlot | ||
+ | ** right-click on the blank space of the myaPlot screen and select "Clone in new LivePlot" | ||
+ | ** right-click on the blank space of the myaPlot screen and select "Load a Configuration" | ||
+ | ** the configuration "beam_conditions" provides the beam current and position information | ||
+ | |||
* The '''BTA''' guidelines are at https://halldweb.jlab.org/hdops/wiki/index.php/BTA_guidelines. <br> After loading the EPICS values, you may change the values, eg round them up or down. | * The '''BTA''' guidelines are at https://halldweb.jlab.org/hdops/wiki/index.php/BTA_guidelines. <br> After loading the EPICS values, you may change the values, eg round them up or down. | ||
** '''BANU values''' >= 5 minutes must be reflected in the PCC value (else the aftermath doesnt work out for RC) | ** '''BANU values''' >= 5 minutes must be reflected in the PCC value (else the aftermath doesnt work out for RC) |
Revision as of 14:41, 28 October 2021
Contents
Current Experiment
PrimEx-eta: A Precision Measurement of the η Radiative Decay Width via the Primakoff Effect
- Experiment number: E12-10-011 (use in BTA shift information)
- Proposal: PAC link
Production running
The plan is to run at 200nA with full LHe4 target and the solenoid and drift chambers on.
- DAQ configuration name: PHYSICS_PRIMEX
- Trigger file: CCAL_FCAL_PS_m9.conf
- Keep the runs to 2h or less.
Shift leader
Guidelines are at https://halldweb.jlab.org/hdops/wiki/index.php/Shift_Guidelines_for_Shift_Leader
- Remember to include a separate list of the runs taken during the shift at the end of the summary (for example, see https://logbooks.jlab.org/entry/3926883)
- Remember to log the strip charts of beam current and position, see https://halldweb.jlab.org/hdops/wiki/index.php/Slow_Controls_Shift#MYA_Archiver
- on a gluon machine type myaPlot
- right-click on the blank space of the myaPlot screen and select "Clone in new LivePlot"
- right-click on the blank space of the myaPlot screen and select "Load a Configuration"
- the configuration "beam_conditions" provides the beam current and position information
- The BTA guidelines are at https://halldweb.jlab.org/hdops/wiki/index.php/BTA_guidelines.
After loading the EPICS values, you may change the values, eg round them up or down.- BANU values >= 5 minutes must be reflected in the PCC value (else the aftermath doesnt work out for RC)
- BANU values < 5 minutes may be set to 0
Shift worker
Guidelines are at https://halldweb.jlab.org/hdops/wiki/index.php/Guidelines_for_Remote_Worker_Shift
- Duties:
- shift checklist (per shift)
- data monitoring plots (per run)
- screen shot of CSS GlueX Overview (per run)
After beam restoration
- check the radiation levels without a radiator and then with the radiator listed on the whiteboard (bottom RHS corner of the RH board) - there are columns of values expected with and without the radiator
- retract the radiator, make sure that the collimator is in blocking position
- ask MCC to do their harp scan
- follow the instructions in https://halldweb.jlab.org/hdops/wiki/index.php/Beam_Line_Detectors_Shift#Radiator_Harp_Scan to do our harp scans
- use the harp scan extrapolation tool and post screenshots of the plots into the logbook (eg https://logbooks.jlab.org/entry/3929556).
Special instructions
timing problems
If there are any, please add sdobbs@jlab.org to the notifications in the logbook entry.
Example double timing peaks: https://logbooks.jlab.org/entry/3933110
Shoulders on timing peaks might be features and not problems: https://logbooks.jlab.org/entry/3933867
AI for CDC HV
Set the CDC HV before the start of each run using the value suggested by the AI.
- There are instructions here https://wiki.jlab.org/epsciwiki/index.php/PrimEx_instructions
- The AI uses measurements from epics averaged over the last minute, so the AI should be used just before starting a run, when the beam current is at its target value and has been steady for the past minute.
- If for any reason this proves to be problematic, please revert to the nominal HV, 2125V, and contact Naomi.
PS and/or PSC scalers freezing
Keep an eye out for the PS and/or PSC scalers freezing. If it happens, then step 2+3 of the instructions 'Run PS Scalers' at https://halldweb.jlab.org/hdops/wiki/index.php/Pair_Spectrometer_Shift can be followed to reset them, it has to be done on gluon100.
Hall Delta