Difference between revisions of "Primer for shift takers"
From Hall D Ops Wiki
(→=Primer for Shift Takers) |
(→Items of the Hall D Shift Check-list) |
||
Line 185: | Line 185: | ||
<td bgcolor="#e0e0f0"> Event display ok? </td> | <td bgcolor="#e0e0f0"> Event display ok? </td> | ||
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
<td bgcolor="#e0e0f0"> 24 </td> | <td bgcolor="#e0e0f0"> 24 </td> | ||
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
</tr><tr> | </tr><tr> | ||
<td bgcolor="#e0e0f0"> Online monitoring screens up </td> | <td bgcolor="#e0e0f0"> Online monitoring screens up </td> | ||
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
<td bgcolor="#e0e0f0"> 25 </td> | <td bgcolor="#e0e0f0"> 25 </td> | ||
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
</tr><tr> | </tr><tr> | ||
<td bgcolor="#e0e0f0"> Online monitoring histo ok? check box for BCal, FCal, CDC, FDC, TOF, ST, PS, TagM, TagH) </td> | <td bgcolor="#e0e0f0"> Online monitoring histo ok? check box for BCal, FCal, CDC, FDC, TOF, ST, PS, TagM, TagH) </td> | ||
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
<td bgcolor="#e0e0f0"> 26 </td> | <td bgcolor="#e0e0f0"> 26 </td> | ||
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
− | <td bgcolor="#e0e0f0"> | + | <td bgcolor="#e0e0f0"> </td> |
</tr><tr> | </tr><tr> | ||
Line 265: | Line 265: | ||
</table> | </table> | ||
<hr> | <hr> | ||
− | |||
== High Voltages == | == High Voltages == |
Revision as of 08:23, 20 May 2015
Contents
=Primer for Shift Takers
This document is an aid to fill the online version of the Check-list required in every shift at the Hall D Counting House. The entries can be found through different ways, one of those is presented here to provide an easy access to the information.
Additional information can be found under Shift Checklist.
How to use this guide
This guide follows the Shifters' Checklist structure and is separated in 5 columns:
- Item: according to the Checklist.
- Main Action Bar on EPICS: which indicates the Slow Control path to find the Item's current value.
- Reference Number and Sample Figure: which show a general image of the screen and an specific one.
- Information for Shift Takers: which shows the links to learn more about those systems.
Items of the Hall D Shift Check-list
Item | Main Action Bar on EPICS
Subsystem - Component |
Reference Number | Sample Figure | Information for Shift Takers |
Beam Energy (GeV) | BEAM - JTABs | 1 | Accelerator Screens | |
e- Beam Current (uA) | BEAM - JTABs | 2 | Accelerator Screens | |
Radiator (RL) | BEAM - Motors | 3 | Amorphous Radiator | |
Tagger current (A)/field(T) | MAGNET - Tagger | 4 | Tagging Spectrometer Shift | |
Solenoid current (A) | MAGNETS - SOLENOID | 5 | Solenoid Operations | |
Solenoid temperature ok?
Record He Return pressure |
MAGNETS - SOLENOID
|
6 - 7 | Solenoid Operations | |
Target type | TARGET - CryoTarget Operations | 8 | Cryogenic Target Shift | |
Collimator aperture (mm) | BEAM - Motors | 9 | Collimator | |
All High Voltage ok? check box for, BCal, FCal, CDC, FDC, TOF, ST, PS, TagM, TagH | High Voltage | 10 | High Voltage | |
Trigger rate (kHz) | (Event Rate plot) | 11 | Data Acquisition | |
Trigger file/DAQ config. | (TRIGGER/CONFIG) | 12 | Data Acquisition | |
Pair Spec. current (A) | MAGNETS - Pair Spectrometer | 13 | Pair Spectrometer | |
Pair Spec. converter (RL) | BEAM - Motors | 14 | PS Convert | |
Visual Halls Inspection | GENERAL - Hall Cameras | 15 | Cameras in the halls | |
DAQ screens up | 16 | DAQ | ||
Epic summary screen up? | GENERAL - GlueX Overview | 17 | Slow Controls Shift | |
Alarm handlers up | (gluon01 console machines) | 18 | Alarm Handler | |
Hall D electronic logbook up | Hall D logbook | 19 | Information for Shift Takers | |
MCC Epics monitoring screen up | BEAM - jTABS Wall Menu - Accelerator Status |
20 | Accelerator Operations | |
Beam position on profilers OK? (upstrm/dwstrm) | BEAM - Beam Profilers | 21 | Beam Profilers Beam position from Profilers |
|
BPM AD00 (tagger dump) | GENERAL - General GlueX Overview | 22 | BPM AD00 | |
Quadrupole MQPAD00 on? | GENERAL - General GlueX Overview | 23 | BPM AD00 | |
Event display ok? | 24 | |||
Online monitoring screens up | 25 | |||
Online monitoring histo ok? check box for BCal, FCal, CDC, FDC, TOF, ST, PS, TagM, TagH) | 26 | |||
Ar Gas supply Bank left(psi) Ar Gas supply Bank right(psi) CO2 Gas supply Bank left(psi) CO2 Gas supply Bank right(psi) |
CDC / FDC Main Gas System GUI |
27 28 29 30 |
Gas System Shift | |
Alcohol Bubbler top (bubbles/level?) Alcohol Bubbler bottom (bubbles/level?) |
(Alcohol bubbler camera in the gas shed) |
31 32 |
Gas System Shift | |
Screen-shot of Epics Overview screen posted on HDlog? | (PrtScr key) | 33 | Screenshot | |
Check list printed and added to check-list binder? | 34 | (Binder inside Hall D Counting House) | ||
Target Temp/Press (High/low cell T/In/out/vacuum P) | TARGET - CryoTarget Operations | 35 | Cryogenic Target Shift | |
High Voltages
High Voltages can be found in the Main Action Bar on EPICS 10.
Item | Main Action Bar on EPICS Subsystem - Component | Reference Number | Sample Figure | Information for Shift Takers |
BCal | BCAL - BCAL Voltages | BCAL | ||
FCal | FCAL - FCAL Voltages | FCAL | ||
CDC | CDC/FDC - CDC Voltages | CDC | ||
FDC | CDC/FDC - FDC Voltages | FDC | ||
TOF | TOF - TOF Voltages | TOF | ||
ST | ST - ST Voltages | ST | ||
PS | PS - PS Voltages | PS | ||
TagM | TAGH/TAGM - TagM Voltages | TagM | ||
TagH | TAGH/TAGM - TagH Voltages | TagH | ||