January 18, 2023 Calorimeter
From GlueXWiki
Meeting Day/Time: every other WEDNESDAY at 11:00 a.m. JLab time
Contents
Connection instructions
Use ZoomGov: https://jlab-org.zoomgov.com/j/1608552106?pwd=UE1nZFIzUUZHVjJEVGJXTGdUYTV3UT09.
Our meeting ID number is 160 855 2106. Click "Expand" for more details.
- Meeting ID: 160 855 2106 Passcode: 944454
- One tap mobile
+16692545252,,1608552106# US (San Jose) +16468287666,,1608552106# US (New York)
- Dial by your location
+1 669 254 5252 US (San Jose) +1 646 828 7666 US (New York) +1 551 285 1373 US +1 669 216 1590 US (San Jose) 833 568 8864 US Toll-free
- Meeting ID: 160 855 2106
- Find your local number: https://jlab-org.zoomgov.com/u/acAwPdiE89
- Join by SIP 1608552106@sip.zoomgov.com
- Join by H.323
161.199.138.10 (US West) 161.199.136.10 (US East) Meeting ID: 160 855 2106 Passcode: 944454
References
- FCAL HDFCAL log book
- BCAL HDBCAL log book
- CCAL HDCCAL log book
- Calibrations: 2020 Data Production; RunPeriod-2019-11 Validation; Offline Monitoring Data Validation
- Photon Reconstruction Task Force
- BCAL calibration links, 2020, PrimEx, SRC
Goals for Calorimetry Group
- Determine preliminary photon reconstruction efficiencies as a function of E, phi and theta in data and simulation with a point-to-point precision of at least 5%.
- Measure systematics of pi0/eta mass calibration as a function of detector position to a precision of at least 5 MeV.
- Demonstrate agreement of photon resolution between data and simulation as a function of E, phi and theta to within 5%.
- Demonstrate agreement of photon reconstruction efficiency between data and simulation as a function of E, phi and theta to within 5%.
Action Items
- Short term CALWG Items
- Long term items
- Calorimeter work packages
- AI - BCAL Monitoring:
Tentative Agenda
- Announcements
- Past Meeting Minutes
- Review Action Items
- Run Operations
- FCAL/FCAL2
- BCAL
- Calibration
- Monitoring
- Reconstruction
- Simulations
- Any other business
Minutes
Attendees: Matt, Mark, Susan, Igal, Tolga, Jon, Karthik, Sasha, Malte, Varun, Zisis
- Announcements: none
- Past Meeting Minutes: no review needed
- Review Action Items: no review needed
- Run Operations
- FCAL/FCAL2: 25 bases changed over the break. Lockup rate of 3/ day. Malte is analyzing the results using entire PrimEx run period, looking at the archiver. The lockups are spread randomly over the FCAL face, with no noticeable concentration near the center. He uses rad508_p2 neutron detector. Checked with empty and filled target (He) but also for Be. Script exists for shift takers once a lockup is detected: entire FCAL high voltage needs to be turned off, then the script resets things. Discussions with Hovanes are ongoing to see if the detection and rest can go into the alarm handler. See modified script and lockup analysis
- BCAL: all in the green. Mark’s new method of pulsing will be monitored by him and Varun.
- Calibration
- FCAL energy calibration: Igal reported on using the LEDs to adjust the gains. It looks promising. There a few more checks to do such as ensuring the LEDs are stable by looking at neighbouring blocks.
- Monitoring
- Reconstruction: no report
- Simulations: no report